Intelligent Bipolar Power Supply
PBZ SR Series
PBZ SR
Price range: 2,620,000円 through 4,120,000円
- User-defined waveform generation function
- Sequence function
- Synchronized operation function
- Central control with master unit utilizing master and slave operation
- Master unit display of total output current of all units (display of combined value) *1
- Safety design that switches all units off when alarm is generated for 1 unit *2
- Guarantee of specifications with Smart Rack (test data standardly included)
- LAN (Capable of LXI), USB, GPIB, and RS232C provided (standard)
- 100 kHz frequency characteristic (CV)
*1 Slave unit displays its own output current. *2 If the alarm for the master unit is cleared, alarms for all units are cleared.
Line-up
| Image | SKU | Output CV [V] | Output CC [A] | 標準価格 | WEBかんたんお見積り |
|---|---|---|---|---|---|
![]() | PBZ20-60 SR | 20V | 60 | 2,620,000円 (税込:2,882,000円) | |
![]() | PBZ40-30 SR | 40V | 30 | 2,620,000円 (税込:2,882,000円) | |
![]() | PBZ60-20.1 SR | 60V | 20.1 | 2,620,000円 (税込:2,882,000円) | |
![]() | PBZ80-15 SR | 80V | 15 | 2,620,000円 (税込:2,882,000円) | |
![]() | PBZ20-80 SR | 20V | 80 | 3,370,000円 (税込:3,707,000円) | |
![]() | PBZ40-40 SR | 40V | 40 | 3,370,000円 (税込:3,707,000円) | |
![]() | PBZ60-26.8 SR | 60V | 26.8 | 3,370,000円 (税込:3,707,000円) | |
![]() | PBZ80-20 SR | 80V | 20 | 3,370,000円 (税込:3,707,000円) | |
![]() | PBZ20-100 SR | 20V | 100 | 4,120,000円 (税込:4,532,000円) | |
![]() | PBZ40-50 SR | 40V | 50 | 4,120,000円 (税込:4,532,000円) | |
![]() | PBZ60-33.5 SR | 60V | 33.5 | 4,120,000円 (税込:4,532,000円) | |
![]() | PBZ80-25 SR | 80V | 25 | 4,120,000円 (税込:4,532,000円) |
Specifications
AC input, rated output
| Item/Model | PBZ20-60 SR | PBZ20-80 SR | PBZ20-100 SR | PBZ40-30 SR | PBZ40-40 SR | PBZ40-50 SR | |
|---|---|---|---|---|---|---|---|
| Input rating | Nominal input voltage | 200 Vac to 240 Vac, single phase | |||||
| Voltage range | 180 Vac to 250 Vac | ||||||
| Frequency range | 47 Hz to 63 Hz | ||||||
| Current | 15 Aac or less | 20 Aac or less | 25 Aac or less | 15 Aac or less | 20 Aac or less | 25 Aac or less | |
| Inrush current | 120 Apeak or less | 160 Apeak or less | 200 Apeak or less | 120 Apeak or less | 160 Apeak or less | 200 Apeak or less | |
| Power | 2700 VA or less | 3600 VA or less | 4500 VA or less | 2700 VA or less | 3600 VA or less | 4500 VA or less | |
| Power factor | 0.95 TYP (when the input voltage is 200 V) | ||||||
| Output rating | Power | 1200 W | 1600 W | 2000 W | 1200 W | 1600 W | 2000 W |
| Voltage | ±20 V | ±40 V | |||||
| Current | ±60 A | ±80 A | ±100 A | ±30 A | ±40 A | ±50 A | |
| Output terminal | Output terminal | Rear panel output terminals | |||||
| Isolation voltage | 500 Vdc Only the output’s COM terminal can be grounded. | ||||||
| Item/Model | PBZ60-20.1 SR | PBZ60-26.8 SR | PBZ60-33.5 SR | PBZ80-15 SR | PBZ80-20 SR | PBZ80-25 SR | |
|---|---|---|---|---|---|---|---|
| Input rating | Nominal input voltage | 200 Vac to 240 Vac, single phase | |||||
| Voltage range | 180 Vac to 250 Vac | ||||||
| Frequency range | 47 Hz to 63 Hz | ||||||
| Current | 15 Aac or less | 20 Aac or less | 25 Aac or less | 15 Aac or less | 20 Aac or less | 25 Aac or less | |
| Inrush current (peak value) | 120 Apeak or less | 160 Apeak or less | 200 Apeak or less | 120 Apeak or less | 160 Apeak or less | 200 Apeak or less | |
| Power | 2700 VA or less | 3600 VA or less | 4500 VA or less | 2700 VA or less | 3600 VA or less | 4500 VA or less | |
| Power factor | 0.95 TYP (when the input voltage is 200 V) | ||||||
| Output rating | Power | 1206 W | 1608 W | 2010 W | 1200 W | 1600 W | 2000 W |
| Voltage | ±60 V | ±80 V | |||||
| Current | ±20.1 A | ±26.8 A | ±33.5 A | ±15 A | ±20 A | ±25 A | |
| Output terminal | Output terminal | Rear panel output terminals | |||||
| Isolation voltage | 500 Vdc Only the output’s COM terminal can be grounded. | ||||||
Constant voltage (CV mode)
| Item/Model | PBZ20-60 SR | PBZ20-80 SR | PBZ20-100 SR | PBZ40-30 SR | PBZ40-40 SR | PBZ40-50 SR | ||
|---|---|---|---|---|---|---|---|---|
| DC voltage | Setting range*1 | Bipolar mode | 0 V to ±(105 % of rating) | |||||
| Unipolar mode | 0 V to +(105 % of rating) | |||||||
| Fine feature | ±5 % of rating | |||||||
| Setting resolution | 0.001 V (0.0001 V for the fine feature) | |||||||
| Setting accuracy*2 | ±(0.05 % of setting + 0.05 % of rating) | |||||||
| Temperature coefficient | ±100 ppm / °C of rating (TYP) | |||||||
| AC voltage | Voltage | Setting range*1 | 0.00 Vpp to (210 % of rating) pp | 0.0 Vpp to (210 % of rating) pp | ||||
| Setting resolution | 0.01 V | 0.1 V | ||||||
| Accuracy of setting*3 | ±0.5 % of rating | |||||||
| Frequency | Selectable range | 0.01 Hz to 100.00 kHz | ||||||
| Constant voltage characteristics | Frequency response *4 | DC to 100 kHz ( -3 dB) (TYP) | ||||||
| Response *5 (TYP) | 3.5 μs, 10 μs, 35 μs, 100 μs | |||||||
| Overshoot *6 | 5 % or less (TYP) | |||||||
| Ripple noise | (p-p)*7 | 30 mV (TYP) | ||||||
| (rms)*8 | 3 mV | 6 mV | ||||||
| Load effect *8 | ±(0.005 % of setting + 1 mV) | |||||||
| Source effect *9 | ±(0.005 % of setting + 1 mV) | |||||||
| Item/Model | PBZ60-20.1 SR | PBZ60-26.8 SR | PBZ60-33.5 SR | PBZ80-15 SR | PBZ80-20 SR | PBZ80-25 SR | ||
|---|---|---|---|---|---|---|---|---|
| DC voltage | Setting range*1 | Bipolar mode | 0 V to ± (105 % of rating) | |||||
| Unipolar mode | 0 V to + (105 % of rating) | |||||||
| Fine feature | ±5 % of rtg | |||||||
| Setting resolution | 0.002 V (0.0002 V for the fine feature) | |||||||
| Setting accuracy*2 | ±(0.05 % of setting + 0.05 % or rating) | |||||||
| Temperature coefficient | ± 100 ppm / °C of rating (TYP) | |||||||
| AC voltage | Voltage | Setting range*1 | 0.0 Vpp to (210 % of rating) pp | |||||
| Setting resolution | 0.1 V | |||||||
| Accuracy of setting*3 | ±0.5 % of rating | |||||||
| Frequency | Selectable range | 0.01 Hz to 100.00 kHz | ||||||
| Constant voltage characteristics | Frequency response *4 | DC to 100 kHz ( -3 dB) (TYP) | ||||||
| Response *5 (TYP) | 3.5 μs, 10 μs, 35 μs, 100 μs | |||||||
| Overshoot *6 | 5 % or less (TYP) | |||||||
| Ripple noise | (p-p)*7 | 40 mV (TYP) | ||||||
| (rms)*8 | 6 mV | |||||||
| Load effect *8 | ±(0.005 % of setting + 1 mV) | |||||||
| Source effect *9 | ±(0.005 % of setting + 1 mV) | |||||||
Constant current (CC mode)
| Item/Model | PBZ20-60 SR | PBZ20-80 SR | PBZ20-100 SR | PBZ40-30 SR | PBZ40-40 SR | PBZ40-50 SR | ||
|---|---|---|---|---|---|---|---|---|
| DC current | Setting range*1 | Bipolar mode | 0 A to ± (105 % of rating) | |||||
| Unipolar mode | 0 A to ± (105 % of rating) | |||||||
| Fine feature | ±5 % of rating | |||||||
| Resolution *11 | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A | ||
| Fine feature *11 | 0.0003 A | 0.0004 A | 0.0005 A | 0.0003 A | 0.0004 A | 0.0005 A | ||
| Setting accuracy*2 | ±0.3 % of rating | |||||||
| Temperature coefficient | ±100 ppm / °C of rating (TYP) | |||||||
| AC current | Current | Setting range*1 | 0 App to (210 % of rating) p-p | |||||
| Resolution *12 | 0.03 A | 0.04 A | 0.05 A | 0.03 A | 0.04 A | 0.05 A | ||
| Accuracy *13 | ±0.5 % of rating | |||||||
| Frequency | Selectable range | 0.01 Hz to 100.00 kHz | ||||||
| Constant current characteristics | Frequency response *14 | DC to 10 kHz (-3 dB) (TYP) | DC to 5 kHz (-3 dB) (TYP) | |||||
| Response *15 (TYP) | 35 μs, 100 μs, 350 μs, 1 ms | 70 μs, 100 μs, 350 μs, 1 ms | ||||||
| Overshoot *16 | 5 % or less (TYP) | |||||||
| Ripple noise (rms) *17 | 5 mA | |||||||
| Load effect *18 | ±(0.01 % of setting + 1 mA) | |||||||
| Source effect *19 | ±(0.01 % of setting + 1 mA) | |||||||
| Item/Model | PBZ60-20.1 SR | PBZ60-26.8 SR | PBZ60-33.5 SR | PBZ80-15 SR | PBZ80-20 SR | PBZ80-25 SR | ||
|---|---|---|---|---|---|---|---|---|
| DC current | Setting range*1 | Bipolar mode | 0 A to ± (105 % of rating) | |||||
| Unipolar mode | 0 A to ± (105 % of rating) | |||||||
| Fine feature | ±5 % of rating | |||||||
| Resolution *11 | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A | ||
| Fine feature *11 | 0.0003 A | 0.0004 A | 0.0005 A | 0.0003 A | 0.0004 A | 0.0005 A | ||
| Setting accuracy*2 | ±0.3 % of rating | |||||||
| Temperature coefficient | ±100 ppm / °C of rating (TYP) | |||||||
| AC current | Current | Setting range*1 | 0 App to (210 % of rating) p-p | |||||
| Resolution *12 | 0.03 A | 0.04 A | 0.05 A | 0.03 A | 0.04 A | 0.05 A | ||
| Accuracy *13 | ±0.5 % of rating | |||||||
| Frequency | Selectable range | 0.01 Hz to 100.00 kHz | ||||||
| Constant current characteristics | Frequency response *14 | DC to 10 kHz (-3 dB) (TYP) | ||||||
| Response *15 (TYP) | 35 μs, 100 μs, 350 μs, 1 ms | |||||||
| Overshoot *16 | 5 % or less (TYP) | |||||||
| Ripple noise (rms) *17 | 5 mA | |||||||
| Load effect *18 | ±(0.01 % of setting + 1 mA) | |||||||
| Source effect *19 | ±(0.01 % of setting + 1 mA) | |||||||
AC common characteristics
| Item/Model | PBZ20-60 SR | PBZ20-80 SR | PBZ20-100 SR | PBZ40-30 SR | PBZ40-40 SR | PBZ40-50 SR | |
|---|---|---|---|---|---|---|---|
| Frequency resolution | 0.01 Hz | ||||||
| Frequency setting accuracy | ±200 ppm | ||||||
| Frequency Accuracy | Linear and logarithmic | ||||||
| Waveforms | Type | Sine wave, square wave, triangle wave, and 16 user-defined arbitrary waveforms | |||||
| Start phase | 0 to 359° | ||||||
| Square wave duty cycle | 0.1 % to 99.9 %, resolution 0.1 % (f < 100 Hz), 1 % to 99 %, resolution 1 % (100 Hz ≤ f < 1 kHz), 10 % to 90 %, resolution 10 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz ≤ f) | ||||||
| Item/Model | PBZ60-20.1 SR | PBZ60-26.8 SR | PBZ60-33.5 SR | PBZ80-15 SR | PBZ80-20 SR | PBZ80-25 SR | |
|---|---|---|---|---|---|---|---|
| Frequency resolution | 0.01 Hz | ||||||
| Frequency setting accuracy | ±200 ppm | ||||||
| Frequency Accuracy | Linear and logarithmic | ||||||
| Waveforms | Type | Sine wave, square wave, triangle wave, and 16 user-defined arbitrary waveforms | |||||
| Start phase | 0 to 359° | ||||||
| Square wave duty cycle | 0.1 % to 99.9 %, resolution 0.1 % (f < 100 Hz), 1 % to 99 %, resolution 1 % (100 Hz ≤ f < 1 kHz), 10 % to 90 %, resolution 10 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz ≤ f) | ||||||
*1: The peak value of the sum of the DC voltage and AC voltage is limited by the DC voltage’s settable range. *2: At an ambient temperature of 23 °C ±5 °C. *3: 1 kHz sine wave, 3.5 μs response. *4: A frequency where the amplitude ratio of the output voltage to the external signal input voltage is -3 dB (when the referencefrequency is 1 kHz, the response is 3.5 μs, and when a rated load is connected). *5: The rise or fall time (at rated load; excluding when output is turned on and off). The frequency response is based on the specified response setting (frequency bandwidth = 0.35/the rise time). Rise time: The time it takes for the output voltage to rise from 10 % to 90 % of the rating when the output voltage is changed from 0 V to the rated voltage. Fall time: The time it takes for the output current to fall from 90 % to 10 % of the rating when the output current is changed from the rated current to 0 A. *6: Under no load or rated load. *7: The measurement frequency bandwidth is 10 Hz to 20 MHz (at the output terminals). *8: The measurement frequency bandwidth is 10 Hz to 1 MHz (at the output terminals). *9: The change in the output voltage in response to a change in the output current from 0 % to 100 % of the current rating (measured at the sensing terminals when remote sensing is used). *10: The change in the output voltage in response to a ±10 % change in the input voltage in reference to the nominal input voltage(measured at the sensing terminals when remote sensing is used). *11: You can set the DC current in 0.001 A (0.0001 A for the fine feature) steps, but it may not change at this resolution depending on the relationship with the internal D/A resolution. *12: You can set the AC current in 0.01 A steps, but it may not change at this resolution depending on the relationship with the internal D/A resolution. *13: 100 Hz sine wave, 35 μs/70 μs response, and shorted output. *14: A frequency where the amplitude ratio of the output current to the external signal input voltage is -3 dB (when the reference frequency is 100 Hz, the response is 35 μs/75 μs, and a rated load is connected). The frequency response changes according to the load impedance. When the load impedance increases, the frequency response decreases. *15: The rise or fall time (at rated load; excluding when output is turned on and off). The rise and fall times change according to the load impedance. Rise time: The time it takes for the output current to rise from 10 % to 90 % of the rating when the output current is changed from 0 A to the rated current. Fall time: The time it takes for the output current to fall from 90 % to 10 % of the rating when the output current is changed from the rated current to 0 A. *16: Under short circuit or rated load. *17: The measurement frequency bandwidth is 10 Hz to 1 MHz (when the output voltage is in the range of 10 % to 100 % of the rated output voltage). *18: The change in the output current in response to a change in the output voltage from 10 % to 100 % of the voltage rating. *19: The change in the output current in response to a ±10 % change in the input voltage in reference to the nominal input voltage(when the output voltage is in the range of 10 % to 100 % of the voltage rating).
Measuring Functions
| Item/Model | PBZ20-60 SR | PBZ20-80 SR | PBZ20-100 SR | PBZ40-30 SR | PBZ40-40 SR | PBZ40-50 SR | ||
|---|---|---|---|---|---|---|---|---|
| Voltage measurement (DC) | Measurement range | 120 % of rating | ||||||
| Resolution | 0.001 V | |||||||
| Accuracy *1 | ± (0.05 % of rdng + 0.05 % of rtg) | |||||||
| Voltage measurement (AC and DC + AC) | Measurement range | AC | 120 % of rating/CF | |||||
| DC+AC | 120 % of rating | |||||||
| Resolution | 0.001 V | |||||||
| Accuracy*1*2 | 5 Hz<f≦10 kHz | ±(0.5 % of reading + 0.1 % of rating) | ||||||
| 10 kHz<f≦50 kHz | ±(1 % of reading + 0.2 % of rating) | |||||||
| 50 kHz<f≦100 kHz | ±(2 % of reading + 0.2 % of rating) | |||||||
| Voltage measurement (PEAK) | Measurement range | 120 % of rating | ||||||
| Resolution | 0.01 V | |||||||
| Accuracy *1*3 | ±0.5 % of rating | |||||||
| Current measurement (DC) | Measurement range | 120 % of rating | ||||||
| Resolution | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A | ||
| Accuracy *1 | ±(0.3 % of reading+0.7 % of rating) | ±(0.3 % of reading+1.0 % of rating) | ±(0.3 % of reading+1.3 % of rating) | ±(0.3 % of reading+0.7 % of rating) | ±(0.3 % of reading+1.0 % of rating) | ±(0.3 % of reading+1.3 % of rating) | ||
| Temperature coefficient | ± (150 ppm / °C of rating) (TYP) | |||||||
| Current measurement (AC, DC + AC) | Measurement range | AC | 120 % of rating/CF | |||||
| DC+AC | 120 % of rating | |||||||
| Resolution | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A | ||
| Accuracy*1*2 | 5 Hz<f≦10 kHz | ±(3 % of reading + 0.1 % of rating) | ||||||
| 10 kHz<f≦50 kHz | ±(10 % of reading + 1 % of rating) | |||||||
| Current measurement (PEAK) | Measurement range | 120 % of rating | ||||||
| Resolution | 0.03 A | 0.04 A | 0.05 A | 0.03 A | 0.04 A | 0.05 A | ||
| Accuracy *1*3 | ±0.5 % of rating | |||||||
| Measurement time (Aperture) | 100 μs to 3600 s | |||||||
| Item/Model | PBZ60-20.1 SR | PBZ60-26.8 SR | PBZ60-33.5 SR | PBZ80-15 SR | PBZ80-20 SR | PBZ80-25 SR | ||
|---|---|---|---|---|---|---|---|---|
| Voltage measurement (DC) | Measurement range | 120 % of rating | ||||||
| Resolution | 0.001 V | |||||||
| Accuracy *1 | ± (0.05 % of rdng + 0.05 % of rtg) | |||||||
| Voltage measurement (AC and DC + AC) | Measurement range | AC | 120 % of rating/CF | |||||
| DC+AC | 120 % of rating | |||||||
| Resolution | 0.001 V | |||||||
| Accuracy*1*2 | 5 Hz<f≦10 kHz | ±(0.5 % of reading + 0.1 % of rating) | ||||||
| 10 kHz<f≦50 kHz | ±(1 % of reading + 0.2 % of rating) | |||||||
| 50 kHz<f≦100 kHz | ±(2 % of reading + 0.2 % of rating) | |||||||
| Voltage measurement (PEAK) | Measurement range | 120 % of rating | ||||||
| Resolution | 0.01 V | |||||||
| Accuracy *1*3 | ±0.5 % of rating | |||||||
| Current measurement (DC) | Measurement range | 120 % of rating | ||||||
| Resolution | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A | ||
| Accuracy *1 | ±(0.3 % of reading+ 0.7 % of rating) | ±(0.3 % of reading+ 1.0 % of rating) | ±(0.3 % of reading+ 1.3 % of rating) | ±(0.3 % of reading+ 0.7 % of rating) | ±(0.3 % of reading+ 1.0 % of rating) | ±(0.3 % of reading+ 1.3 % of rating) | ||
| Temperature coefficient | ± (150 ppm / °C of rating) (TYP) | |||||||
| Current measurement (AC and DC + AC) | Measurement range | AC | 120 % of rating/CF | |||||
| DC+AC | 120 % of rating | |||||||
| Resolution | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A | ||
| Accuracy*1*2 | 5 Hz<f≦10 kHz | ±(3 % of reading + 0.1 % of rating) | ||||||
| 10 kHz<f≦50 kHz | ±(10 % of reading + 1 % of rating) | |||||||
| Current measurement (PEAK) | Measurement range | 120 % of rating | ||||||
| Resolution | 0.03 A | 0.04 A | 0.05 A | 0.03 A | 0.04 A | 0.05 A | ||
| Accuracy *1*3 | ±0.5 % of rating | |||||||
| Measurement time (Aperture) | 100 μs to 3600 s | |||||||
Protective functions and interfaces
| Protection functions | Overvoltage protection, Overcurrent protection, Overheat protection, Power limit (sink power) |
|---|---|
| Interface | RS232C, GPIB, USB, LAN |
General specifications
| Item/Model | PBZ20-60 SR | PBZ20-80 SR | PBZ20-100 SR | PBZ40-30 SR | PBZ40-40 SR | PBZ40-50 SR | |
|---|---|---|---|---|---|---|---|
| Operating temperature range | 0 °C to 40 °C (32 °F to 104 °F) | ||||||
| Operating humidity range | 20 %rh to 85 %rh (no condensation) | ||||||
| Storage temperature range | -25 °C to +70 °C (-13 °F to +158 °F) | ||||||
| Storage humidity range | 90 %rh or less (no condensation) | ||||||
| Insulation resistance | Between the primary circuit and the output terminals | 500 Vdc, 30 MΩ or greater (at 70 %rh humidity or less) | |||||
| Between the primary circuit and chassis | |||||||
| Between the output terminals and chassis | 500 Vdc, 0.33 MΩ or greater | 500 Vdc, 0.25 MΩ or greater | 500 Vdc, 0.20 MΩ or greater | 500 Vdc, 0.33 MΩ or greater | 500 Vdc, 0.25 MΩ or greater | 500 Vdc, 0.20 MΩ or greater | |
| Withstanding voltage | Between the primary circuit and the output terminals | No abnormalities at 1500 Vac for 1 minute | |||||
| Between the primary circuit and chassis | |||||||
| Leakage current (250 V / 60 Hz) | 10 mA or less | ||||||
| Ground bond | 100 Aac, 0.1 Ω or less | ||||||
| Cooling system | Forced air cooling using a heat sensing variable speed fan. | ||||||
| Battery backup | Settings are retained when the power is off. At least three years of battery life (at 25 °C). | ||||||
| Weight | Approx. 110 kg (242.51 lbs) | Approx. 130 kg (286.60 lbs) | Approx. 160 kg (352.74 lbs) | Approx. 110 kg (242.51 lbs) | Approx. 130 kg (286.60 lbs) | Approx. 160 kg (352.74 lbs) | |
| Dimensions (mm(inch))(maximum dimensions) | 432.6(17.03″)(545(21.46″))W× 579.4(22.81″)(685(26.97″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 712.1(28.04″)(815(32.09″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 844.8(33.26″)(950(37.40″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 579.4(22.81″)(685(26.97″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 712.1(28.04″)(815(32.09″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 844.8(33.26″)(950(37.40″))H× 700(27.56″)(735(28.94″))D mm (inches) | |
| Accessories | PBZ-SR series manuals: Setup Guide (1 pc.), Quick Reference (Japanese: 1 pc / English: 1 pc.), Safety Information (1 pc.) J1 connector kit: Socket (1 pc.), Protection covers (2 pairs), Pins (30 pc.) Heavy object warning label (1 pc.), CD-ROM (1 pc.) | ||||||
| Item/Model | PBZ60-20.1 SR | PBZ60-26.8 SR | PBZ60-33.5 SR | PBZ80-15 SR | PBZ80-20 SR | PBZ80-25 SR | |
|---|---|---|---|---|---|---|---|
| Operating temperature range | 0 °C to 40 °C (32 °F to 104 °F) | ||||||
| Operating humidity range | 20 %rh to 85 %rh (no condensation) | ||||||
| Storage temperature range | -25 °C to +70 °C (-13 °F to +158 °F) | ||||||
| Storage humidity range | 90 %rh or less (no condensation) | ||||||
| Insulation resistance | Between the primary circuit and the output terminals | 500 Vdc, 30 MΩ or greater (at 70 %rh humidity or less) | |||||
| Between the primary circuit and chassis | |||||||
| Between the output terminals and chassis | 500 Vdc, 0.33 MΩ or greater | 500 Vdc, 0.25 MΩ or greater | 500 Vdc, 0.20 MΩ or greater | 500 Vdc, 0.33 MΩ or greater | 500 Vdc, 0.25 MΩ or greater | 500 Vdc, 0.20 MΩ or greater | |
| Withstanding voltage | Between the primary circuit and the output terminals | No abnormalities at 1500 Vac for 1 minute | |||||
| Between the primary circuit and chassis | |||||||
| Leakage current (250 V / 60 Hz) | 10 mA or less | ||||||
| Ground bond | 100 Aac, 0.1 Ω or less | ||||||
| Cooling system | Forced air cooling using a heat sensing variable speed fan. | ||||||
| Battery backup | Settings are retained when the power is off. At least three years of battery life (at 25 °C). | ||||||
| Weight | Approx. 110 kg (242.51 lbs) | Approx. 130 kg (286.60 lbs) | Approx. 160 kg (352.74 lbs) | Approx. 110 kg (242.51 lbs) | Approx. 130 kg (286.60 lbs) | Approx. 160 kg (352.74 lbs) | |
| Dimensions (mm(inch))(maximum dimensions) | 432.6(17.03″)(545(21.46″))W× 579.4(22.81″)(685(26.97″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 712.1(28.04″)(815(32.09″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 844.8(33.26″)(950(37.40″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 579.4(22.81″)(685(26.97″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 712.1(28.04″)(815(32.09″))H× 700(27.56″)(735(28.94″))D mm (inches) | 432.6(17.03″)(545(21.46″))W× 844.8(33.26″)(950(37.40″))H× 700(27.56″)(735(28.94″))D mm (inches) | |
| Accessories | PBZ-SR series manuals: Setup Guide (1 pc.), Quick Reference (Japanese: 1 pc / English: 1 pc.), Safety Information (1 pc.) J1 connector kit: Socket (1 pc.), Protection covers (2 pairs), Pins (30 pc.) Heavy object warning label (1 pc.), CD-ROM (1 pc.) | ||||||
*1: At an ambient temperature of 23 °C ± 5 °C. *2: When the input signal is in the 100 kHz bandwidth and has a crest factor of 3 or less (the measurement time is at least 10 times the input signal period). *3: Calibrated with a 1 kHz sine wave. *4: At 70 %rh humidity or less