Item/Model | PAV10-72 | PAV20-40 | PAV36-24 | PAV60-14 | PAV100-8 | PAV160-5 | PAV320-2.5 | PAV650-1.25 |
---|---|---|---|---|---|---|---|---|
Foldback protection | Turns off the output when the operation switches from constant voltage mode to constant current mode or vice versa. Can be set as necessary. | |||||||
Overvoltage protection (OVP) | Inverter shutoff system. Prevents the output voltage from being set higher than the OVP value. Also shuts off the output when an output overvoltage (exceeding the OVP value) occurs. | |||||||
Overvoltage protection voltage setting range | 0.5 V to 12 V | 1 V to 24 V | 2 V to 40 V | 5 V to 66 V | 5 V to 110 V | 5 V to 176 V | 5 V to 353 V | 5 V to 717 V |
Undervoltage limit (UVL) | Prevents the output voltage from being set lower than the UVL value. Disabled during external control. | |||||||
Undervoltage protection (UVP) | Shuts off the output when the output voltage falls below the UVP value. | |||||||
Overheat protection | Shuts off the output before the temperature of the internal components exceeds the safe operation temperature. |
25460
PAV_800W_Protection functions
Related specifications : PAV Series
- PAV_J3 connector
- PAV_J1 connector
- PAV_800W_Simplified line-up
- PAV_600W_Simplified line-up
- PAV_400W_Simplified line-up
- PAV_200W_Simplified line-up
- PAV_800W_Front panel
- PAV_800W_Setting and readback (USB, RS232, RS485, optional LAN interface)
- PAV_800W_Protection functions
- PAV_800W_Constant current mode
- PAV_800W_Constant voltage mode
- PAV_800W_AC input
- PAV_800W_Output
- PAV_800W_line-up
- PAV_600W_Front panel
- PAV_600W_Setting and readback (USB, RS232, RS485, optional LAN interface)
- PAV_600W_Protection functions
- PAV_600W_Constant current mode
- PAV_600W_Constant voltage mode
- PAV_600W_AC input
- PAV_600W_Output
- PAV_600W_line-up
- PAV_400W_Front panel
- PAV_400W_Setting and readback (USB, RS232, RS485, optional LAN interface)
- PAV_400W_Protection functions
- PAV_400W_Constant current mode
- PAV_400W_Constant voltage mode
- PAV_400W_AC input
- PAV_400W_Output
- PAV_400W_line-up
- PAV_200W_Front panel
- PAV_200W_Setting and readback (USB, RS232, RS485, optional LAN interface)
- PAV_200W_Protection functions
- PAV_200W_Constant current mode
- PAV_200W_Constant voltage mode
- PAV_200W_AC input
- PAV_200W_Output
- PAV_200W_line-up
- PAV_Safety / EMC
- PAV_Structure
- PAV_Environmental conditions
- PAV_External control