Bidirectional High-Capacity DC Power Supply

For progressive

PXB Series

electric applications

Our goal was to create a bidirectional power supply
that could meet “X” various requirements.

Ultra-compact: 20 kW in a single 3U size frame.
It can handle not only high voltages of 1500V but also has both power and regenerative modes.
Guarantees optimal operation at any stage of research, development, and manufacturing.

Bidirectional High-Capacity DC Power Supply PXB Series

Condenses a 20 kW large-capacity output into a 3U-size chassis. Not only handling high voltages of 1500V, but also capable of both power and regeneration in both directions in a single unit.

We provide a new power supply test environment for electrical and electronic equipment that is becoming increasingly high-powered. In addition, a variety of analog, digital, and communication interfaces are provided for optimal operation at any stage of research, development, and manufacturing! A new generation of bidirectional DC power supplies that support the progression of advanced technologies.

High power density

high-power & compact
Condenses a 20 kW large-capacity output into a 3U-size chassis.

Bidirectional output

A single unit handles both power and regeneration.
For test applications such as inverters with increasing capacity.

1500V

Maximum voltage: 1500V high voltage compatible.

Selectable power input

Choose from 3-phase 3-wire 200 V or 400 V models. No output limitation for either input voltage.

Features

Click on an item to open its description.

Output power range 2 to 3 times mains-powered operation

Output power range 2 to 3 times mains-powered operationMains-powered power supply with a wide range of operating ranges and combinations of voltage and current settings. If the voltage of the connected DUT is lower than the voltage setting of the PXB series, current flows from the PXB series to the DUT. If the voltage of the connected DUT is higher than the voltage setting of the PXB series, current flows from the DUT to the PXB series.

Achieves high-speed rise and fall times

Achieves high-speed rise and fall timesAchieves a rise/fall time of 10 ms, which is several tens of times faster than conventional switching power supplies. Enabling high-speed power fluctuation testing that cannot be handled by ordinary DC power supplies.

Highly stable operation with high resistance to capacitive loads

Highly stable operation with high resistance to capacitive loadsDesigned for highly stable operation, without oscillation or overshoot even when a load with a large capacitive component is connected.
Slew rate and response can be varied to match the characteristics of the connected load, suppressing oscillation and overshoot.

Optimized for different purposes and applications, with selectable response speeds

Optimized for different purposes and applications, with selectable response speedsThe required power supply response time varies depending on the test conditions and load specifications. The response speed of the PXB Series power supply can be changed to suit different applications.

Up to 10 units can be operated in parallel, achieving 200 kW *

Up to 10 units can be operated in parallel, achieving 200 kWIncluding master machine, up to 10 units (200 kW) can be operated in parallel. Connection is with one-control parallel operation, and the panel of the master machine can control and display the entire system. With the automatic recognition function, the need for complicated settings is eliminated, allowing the construction of high-capacity systems.
* Parallel operation is possible between models with different input rated voltages. Please contact us if you wish to operate more than 10 units in parallel.

Click on an item to open its description.

Sequence function

Sequence functionPreset operations can be run continuously. Total of 30 programs, and up to 10,000 steps can be created for all programs. Programs stored in the unit’s memory, and data can be exported to a USB memory stick from the front panel.

Pulse function / Sign function

Pulse function / Sign function“Pulse” operation can be set, which repeatedly executes a binary setting, or “sine” operation, changing the current in a sinusoidal manner.

Regenerative function (on-premises) contributes to carbon neutrality.

Regenerative function (on-premises) contributes to carbon neutrality.When power is regenerated to the main unit from an inverter or battery, the load power is converted to reusable power and regenerated to the AC LINE. This can contribute to reducing the amount of heat exhaust and saving energy.
*Regenerative efficiency 90% or more (at rated load in Typ)

*The PXB series is designed for on-site regenerative power. Use in an environment where the power in the premises is greater than the regenerative power.

Selectable power input

Selectable power inputFull output at rated power regardless of input voltage. Choose from 3-phase 3-wire 200 V or 400 V models. No output limitation for either input voltage.

Equipped with touch panel display

By pressing or swiping the display with a finger, the user can select an item on the screen or set a numerical value. The display is pressure-sensitive and can be operated even with gloves on.

Output power range 2 to 3 times mains-powered operation

DC SEAM Mains-powered power supply with a wide range of operating ranges and combinations of voltage and current settings. If the voltage of the connected DUT is lower than the voltage setting of the PXB series, current flows from the PXB series to the DUT. If the voltage of the connected DUT is higher than the voltage setting of the PXB series, current flows from the DUT to the PXB series.

Achieves high-speed rise and fall times

DC SEAM Achieves a rise/fall time of 10 ms, which is several tens of times faster than conventional switching power supplies. Enabling high-speed power fluctuation testing that cannot be handled by ordinary DC power supplies.

Highly stable operation with high resistance to capacitive loads

DC SEAM Designed for highly stable operation, without oscillation or overshoot even when a load with a large capacitive component is connected.
Slew rate and response can be varied to match the characteristics of the connected load, suppressing oscillation and overshoot.

Optimized for different purposes and applications, with selectable response speeds

DC SEAM The required power supply response time varies depending on the test conditions and load specifications. The response speed of the PXB Series power supply can be changed to suit different applications.

Up to 10 units can be operated in parallel, achieving 200 kW *

DC SEAM Including master machine, up to 10 units (200 kW) can be operated in parallel. Connection is with one-control parallel operation, and the panel of the master machine can control and display the entire system. With the automatic recognition function, the need for complicated settings is eliminated, allowing the construction of high-capacity systems.
* Parallel operation is possible between models with different input rated voltages. Please contact us if you wish to operate more than 10 units in parallel.

Sequence function

DC SEAM Preset operations can be run continuously. Total of 30 programs, and up to 10,000 steps can be created for all programs. Programs stored in the unit’s memory, and data can be exported to a USB memory stick from the front panel.

Pulse function / Sign function

DC SEAM “Pulse” operation can be set, which repeatedly executes a binary setting, or “sine” operation, changing the current in a sinusoidal manner.

Regenerative function (on-premises) contributes to carbon neutrality.

DC SEAM When power is regenerated to the main unit from an inverter or battery, the load power is converted to reusable power and regenerated to the AC LINE. This can contribute to reducing the amount of heat exhaust and saving energy.
*Regenerative efficiency 90% or more (at rated load in Typ)

*The PXB series is designed for on-site regenerative power. Use in an environment where the power in the premises is greater than the regenerative power.

Selectable power input

DC SEAM Full output at rated power regardless of input voltage. Choose from 3-phase 3-wire 200 V or 400 V models. No output limitation for either input voltage.

Touch panel display

By pressing or swiping the display with a finger, the user can select an item on the screen or set a numerical value. The display is pressure-sensitive and can be operated even with gloves on.

SEAM mode

DC SEAM Equipped with SEAM mode allowing current to flow in both directions without changing voltage values. Suitable for charging and discharging storage batteries. Can suppress current overshoots and undershoots which may often occur during operation mode switching after charge/ discharge.

Variable internal resistance feature

Function can change the output voltage value in constant voltage operation, according to the output current value based on the set resistance value. Simple simulation of Internal resistance of rechargeable batteries and wire harnesses etc. Variable internal resistance function

ZOOM
Setting rangePXB20K-500 mΩ to 63 mΩ
PXB20K-2500 mΩ to 1575 mΩ
PXB20K-5000 mΩ to 5250 mΩ
PXB20K-10000 mΩ to 21000 mΩ
PXB20K-15000 mΩ to 63000 mΩ

I-V characteristic function

By registering multiple arbitrary points on the I-V characteristics, arbitrary I-V characteristics can be set for each CC and CV operation mode. Arbitrary points can be registered from 3 to 100, making it possible to simulate the I-V characteristics of rechargeable batteries and other devices. I-V characteristic function

By registering multiple arbitrary points on the I-V characteristics, arbitrary I-V characteristics can be set for each CC and CV operation mode.

Reliable and solid performance even under high temperatures

Solid performance under operating temperatures of 0°C to 50°C. Exhibits full performance even in environments with severe ambient temperatures, such as when installed in equipment.
Caution: PXB20K-50 and PXB20K-250 operates in the temperature range of 0°C to +40°C. 50 ̊C

Safety Protection Function

  • OVP (Over voltage protection)
  • UVP (Under voltage protection)
  • WDOG (Communication error protection)
  • OPP (Over power protection)
  • OCP (Over current protection)
  • EXT LOW (External input alarm detection)

Priority Operation Mode

Mode of operation can be set, as constant voltage (CV), constant current (CC), or constant power (CP), when output is turned on. Overshoot can be prevented by setting CC mode priority when batteries, power supplies, etc. are connected.

External Control Function

The EXT CONT connector on the rear panel can be used to control the PXB series with external devices. The general-purpose digital input and output terminals can be assigned any function, facilitating system construction in combination with other measurement devices.
Digital I/O standard for both NPN and PNP type PLCs. Analog I/O is isolated from output terminals as standard, allowing safe analog control from PLC.

External Control Function

ZOOM
Terminal No.MethodI/ONameDescription
1DigitalOOUT Ch.1General-purpose output terminal
2DigitalOOUT Ch.2General-purpose output terminal
3DigitalOOUT Ch.3General-purpose output terminal
4DO COMDigital output common
5DI COMDigital input common
6DigitalIIN Ch.1General-purpose input terminal
7DigitalIIN Ch.2General-purpose input terminal
8DigitalIIN Ch.3General-purpose input terminal
9O+12V OUT12 V reference voltage available for digital input
10Not used
11A COMAnalog signal common
12AnalogOVMONVoltage monitor
13AnalogOIMONCurrent monitor
14DigitalOOUT Ch.4General-purpose output terminal
15DigitalOOUT Ch.5General-purpose output terminal
16DigitalOOUT Ch.6General-purpose output terminal
17DO COMDigital output common
18DI COMDigital input common
19DigitalIIN Ch.4General-purpose input terminal
20DigitalIIN Ch.5General-purpose input terminal
21DigitalIH ALARM INHIGH alarm EXT HIGH occurrence
2212V COM12 V reference voltage common
23A COMAnalog signal common
24AnalogIEXT CVVoltage control in the constant voltage mode
25AnalogIEXT CC/CPCurrent control in the constant current / power modes
ZOOM
MethodFunction
Analog inputVoltage and current value settings
Analog outputMonitoring of voltage and current values
General-purpose isolated digital input (Ch.1 to ch.5)
*Photocoupler isolated input (Supports both current sink and source)
  • Output ON/OFF from DC OUTPUT terminal
  • LOW alarm generation / deactivation
  • Start / Stop totalizer measurement
  • Reset integrated value
  • Measurement trigger input
  • Preset memory recall
Digital input (Ch.6)HIGH alarm generation (Fixed)
General-purpose isolated digital output (Ch.1 to ch.6) *Semiconductor relay output
  • Monitor output status of DC OUTPUT terminal
  • Power-on monitor
  • Alarm monitoring
  • Operating mode monitoring
  • Preset memory monitoring

General-purpose isolated digital input terminals are available from Ch.1 to Ch.5. Any setting value from the items listed on the right can be selected.

General-purpose isolated digital input terminals

General-purpose isolated digital output terminals are available from Ch.1 to Ch.6. Any setting value from the items listed on the right can be selected.

General-purpose isolated digital output terminals

Panel explanation

Applications

Inverter and motor evaluation test

Inverter and motor evaluation test

Aging tests for bidirectional DC/DC converters

Aging tests for bidirectional DC/DC converters

Specifications

Output rating
ZOOM
ItemPXB20K-50PXB20K-250PXB20K-500PXB20K-1000PXB20K-1500
Rated power±20000 W±20000 W±20000 W±20000 W±20000 W
Rated voltage (source) *10 V to 50 V0 V to 250 V0 V to 500 V0 V to 1000 V0 V to 1500 V
Operating voltage (sink) *23 V to 50 V15 V to 250 V10 V to 500 V20 V to 1000 V30 V to 1500 V
Rated current*1±800 A±200 A±120 A±60 A±30 A

*1. Limited by the maximum output power. *2. Operating voltage at which the rated sink current can be applied.

Output voltage
ZOOM
ItemPXB20K-50PXB20K-250PXB20K-500PXB20K-1000PXB20K-1500
Maximum settable voltage52.5 V262.5 V525 V1050 V1575 V
Setting accuracy±(0.2 % of setting + 0.1 % of rating)
Setting resolution0.005 V0.02 V0.05 V0.1 V0.1 V
Power fluctuation*1±10 mV±50 mV±100 mV±200 mV±300 mV
Load variation*2±40 mV±125 mV±250 mV±500 mV±750 mV
Remote sensing Maximum compensation voltage (reciprocating)10 % of rating
Internal resistance setting upper limit63 mΩ1575 mΩ5250 mΩ21000 mΩ63000 mΩ
Internal resistance setting resolution1 mΩ1 mΩ1 mΩ2 mΩ5 mΩ
Response switchingFAST, SLOW
Slew rate switching (TYP)12.5 V/ms or more *362.5 V/ms or more *3125 V/ms or more *3250 V/ms or more *3375 V/ms or more *3
12.5 V/ms62.5 V/ms125 V/ms250 V/ms375 V/ms
1.25 V/ms6.25 V/ms12.5 V/ms25.0 V/ms37.5 V/ms
0.125 V/ms0.625 V/ms1.25 V/ms2.50 V/ms3.75 V/ms
0.0125 V/ms0.0625 V/ms0.125 V/ms0.250 V/ms0.375 V/ms
Source only *4Transient response *58 ms or less8 ms or less8 ms or less10 ms 以下10 ms 以下
Ripple noise *6p-p*7250 mV375 mV1000 mV1500 mV2500 mV
rms*830 mV125 mV250 mV500 mV750 mV
Rise time *9Full load *1010 ms
No load10 ms
Fall time *11Full load *1010 ms
No load10 ms

*1. 180 Vac to 252 Vac for 200 Vac input, 342 Vac to 504 Vac for 400 Vac input. At the constant load. *2. The amount of change that occurs when the load is changed from no load to full load (rated output power/rated output voltage) with rated output voltage. The value is measured at the sensing point. *3. MAX will appear on the display. *4. In the case that the CV mode response setting is set to FAST. *5. The amount of time required for the output voltage to return to a value within “rated output voltage ±(0.1 % + 10 mV).” The load current fluctuation is 50 % to 100 % of the maximum current with the set output voltage. *6. At the rated output current. Values measured using JEITA RC-9131C probe and 100:1 probe. *7. Measurement frequency band: 10 Hz to 20 MHz *8. Measurement frequency band: 10 Hz to 1 MHz *9. 10 % to 90 % of the rated output voltage. *10.For a pure resistance. *11. 90 % to 10 % of the rated output voltage.

Output current
ZOOM
ItemPXB20K-50PXB20K-250PXB20K-500PXB20K-1000PXB20K-1500
Settable maximum source current *1+840 A+210 A+126 A+63 A+31.5 A
Settable maximum sink current *1-840 A-210 A-126 A-63 A-31.5 A
Seamless setting current range *1-840 A to +840 A-210 A to +210 A-126 A to +126 A-63 A to +63 A-31.5 A to +31.5 A
Setting accuracy±(0.75 % of rating)
Setting resolution0.1 A0.02 A0.01 A0.005 A0.002 A
Line regulation±1600 mA±400 mA±240 mA±120 mA±60 mA
Load regulation±1600 mA±400 mA±240 mA±120 mA±60 mA
Rise time (Short-circuit) (TYP) *25 ms
Fall time (Short-circuit) (TYP) *35 ms
Charge/discharge switching time (TYP)10 ms
Response switchingFAST, SLOW
Slew rate switching (TYP) *4200 A/ms or more *350 A/ms or more *330 A/ms or more *315 A/ms or more *37.5 A/ms or more *3
200 A/ms50 A/ms30 A/ms15 A/ms7.5 A/ms
20 A/ms5 A/ms3 A/ms1.5 A/ms0.75 A/ms
2 A/ms0.5 A/ms0.3 A/ms0.15 A/ms0.075 A/ms
0.2 A/ms0.05 A/ms0.03 A/ms0.015 A/ms0.0075 A/ms

*1. During parallel operation, this will be the value multiplied by the number of units in the configuration. *2. In the case that the CC mode response setting is set to FAST: Applied in response to changes from 10 % to 90 % of rated output current. *3. In the case that the CC mode response setting is set to FAST: Applied in response to changes from 90 % to 10 % of rated output current. *4. MAX will appear on the display.

Output power
ZOOM
ItemCommon to all models
Settable maximum source power+21000 W
Settable maximum sink power-21000 W
Seamless setting power range-21000 W to +21000 W
Setting accuracy *1±(0.5 % of power rating + 0.5 % of current rating × Vout)
Resolution2 W

*1. Equal to or higher than 5 % of the rated power is guaranteed. Less than 5 % of the rated power is guaranteed as a TYP value.

200 V three-phase three-wire input
ZOOM
ItemCommon to all models
Nominal input rating200 Vac to 240 Vac, 50 Hz to 60 Hz
Input voltage range180 Vac to 252 Vac
Input frequency range47 Hz to 63 Hz
Input current (MAX)*180 A (180 V)
Input power (MAX)*124 kVA
Inrush current (TYP)*290 A
Power factor (TYP)*10.96
Output hold time10 ms or more

*1. At the rated output power for the rated output current. *2. Maximum peak current value when the POWER switch is turned on. (Excluding the surge current to the input filter capacitor.)

400 V three-phase three-wire input
ZOOM
ItemCommon to all models
Nominal input rating380 Vac to 480 Vac, 50 Hz to 60 Hz
Input voltage range342 Vac to 504 Vac
Input frequency range47 Hz to 63 Hz
Input current (MAX)*140 A (342 V)
Input power (MAX)*124 kVA
Inrush current (TYP)*270 A
Power factor (TYP)*10.96
Output hold time10 ms or more

*1. At the rated output power for the rated output current. *2. Maximum peak current value when the POWER switch is turned on. (Excluding the surge current to the input filter capacitor.)

Display
ZOOM
ItemPXB20K-50PXB20K-250PXB20K-500PXB20K-1000PXB20K-1500
VoltmeterMaximum display±60.000 V±300.00 V±600.00 V±1200.00 V±1800.00 V
Display accuracy±(0.1 % of reading + 0.2 % of rating)
AmmeterMaximum display±1120.000 A±336.000 A±168.000 A±84.000 A±42.000 A
Display accuracy±(0.75 % of rating)
WattmeterMaximum display *1±24.000 kW
Display accuracyDisplay the integrated value of voltmeter and ammeter
Operation displayOutput ON / OFFThe OUTPUT LED on the front panel lights in green
Operation modeIndicate the followings on the upper left part of the display
CV: CV icon
CC: CC icon
CP: CP icon
Remote (LAN)Indicate the followings on the upper left part of the display
Not connected: Red LAN icon
Preparing for connection: Orange LAN icon
Connected: Green LAN icon
AlarmIndicate the details of activated protection function on the display
SCPI errorIndicate the error occurring at present on the display
POWER offIndicate residual charge warning and an instruction to turn off the display, then reboot
key lockIndicate the key lock status on the upper right part of the display
SensingWhen sensing is enabled, indicate the sensing icon on the upper right part of the display
During parallel operationDisplaying the slave state on the slave unit
External controlWhen digital input/output is enabled, indicate the EXT icon on the upper right part of the display

*1 The unit will be W if it is less than 10 kW.

Protection specifications LOW alarm
ZOOM
ItemPXB20K-50PXB20K-250PXB20K-500PXB20K-1000PXB20K-1500
OVP (Over Voltage Protection)Protective operationOutput off, indicate “OVP” on the display. SLV OVP is displayed on the slave unit.
Selectable range5 V to 55 V25 V to 275 V50 V to 550 V100 V to 1100 V150 V to 1650 V
Setting accuracy±(0.1 % of setting + 0.2 % of rating)
Resolution0.005 V0.02 V0.05 V0.1 V0.1 V
OCP (Over Current Protection)Protective operationOutput off, indicate “OCP” on the display. SLV OCP is displayed on the slave unit.
Setting range (Source) *180 A to 880 A20 A to 220 A12 A to 132 A6 A to 66 A3 A to 33 A
Setting range (Sink) *1-80 A to -880 A-20 A to -220 A-12 A to -132 A-6 A to -66 A-3 A to -33 A
Setting accuracy±(0.75 % of rating)
Resolution0.1 A0.02 A0.01 A0.005 A0.002 A
OPP (Over Power Protection)Protective operationOutput off, indicate “OPP” on the display. SLV OPP is displayed on the slave unit.
Setting range (Source) *12 kW to 24 kW
Setting range (Sink) *1-2 kW to -24 kW
Setting accuracy±(1.0 % of power rating +1.0 % of current rating × Vout)
Resolution2 W
UVP (Under Voltage Protection)Protective operationOutput off, indicate “UVP” on the display. SLV UVP is displayed on the slave unit.
Selectable range0 V to 50 V0 V to 250 V0 V to 500 V0 V to 1000 V0 V to 1500 V
SelectableEnable/Disable
Setting accuracy±(0.1 % of setting + 0.2 % of rating)
Resolution0.005 V0.02 V0.05 V0.1 V0.1 V
Watchdog Alarm (Communication error protection)Protective operationOutput off, indicate “WDOG” on the display
Selectable range1 s to 3600 s
SelectableEnable/Disable
External Alarm LOW Level (external input alarm detection)Protective operationOutput off, indicate “EXT LOW” on the display

*An alarm not requiring a reboot to be cleared. *1. During parallel operation, this will be the value multiplied by the number of units in the configuration.

Protection Specifications HIGH alarm
ZOOM
ItemCommon to all models
Reverse Alarm (Reverse-connection detection protection)Protective operationOutput off, indicate “REVE” on the display
OHP (Overheat protection)Protective operationOutput off, indicate “OHP” on the display. SLV OHP is displayed on the slave unit.
Line OVP (Grid overvoltage protection)Protective operationOutput off, indicate “LOVP” on the display. SLV LOVP is displayed on the slave unit.
Selectable rangeInput voltage rating 200 Vac model: 200 V to 258 V
Input voltage rating 400 Vac model: 380 V to 516 V
Line UVP (Grid undervoltage protection)Protective operationOutput off, indicate “LUVP” on the display. SLV LUVP is displayed on the slave unit.
Selectable rangeInput voltage rating 200 Vac model: 175 V or less.
Input voltage rating 400 Vac model: 333 V or less.
Line Frequency Error (Grid abnormal frequency protection)Protective operationOutput off, indicate “FREQ” on the display. SLV FREQ is displayed on the slave unit.
Detection value42 Hz/68 Hz
External Alarm HIGH Level (External input alarm detection)Protective operationOutput off, indicate “EXT HIGH” on the display
SENS Alarm (incorrect sensing connection detection)Protective operationOutput off, indicate “SENS” on the display
Setting rangeEnable/Disable
Parallel Communication Error (Parallel operation communication error detected)Protective operationOutput off, indicate “PARA COM” on the display
Para Other Slave Alarm (Parallel operation slave error occurred)Protective operationOutput off, indicate “SLV OTHR” on the display
Incorrect Slave Alarm (Not applicable device connected)Protective operationOutput off, indicate “SLV INC” on the display
Too many connections (Too many parallel connections)Protective operationOutput off, indicate “TOO MANY” on the display
Hardware ERR *1 (Hardware error)Protective operationOutput off, indicate “ERRH” on the display. SLV ERRH is displayed on the slave unit.
Software ERR *2 (Software error)Protective operationOutput off, indicate “ERRS” on the display. SLV ERRS is displayed on the slave unit.

*An alarm requiring a reboot to be cleared. *1. It occurs when an abnormality related to the hardware is detected and the internal unit comes to an emergency stop. *2. It occurs when an abnormality related to the software is detected and the internal unit comes to an emergency stop.

External analog I/O
ZOOM
ItemCommon to all models
InputInput points2 points
Voltage (CV) controlSetting range0 % to 100 % of the rated output voltage
Input voltage range0 V to +5 V or 0 V to +10 V (Selectable)
Accuracy±(1 % of rating)
Current (CC) control
Power (CP) control *1
Setting range−100 % to +100 % of the rated current and rated power
Input voltage range−5 V to +5 V or −10 V to +10 V (Selectable)
Accuracy±(1 % of rating)
OutputOutput points2 points
Voltage monitor (VMON)Monitor range0 % to 100 % of the rated output voltage
Output voltage range0 V to +5 V or 0 V to +10 V (Selectable)
Accuracy1 % of rating
Current monitor (IMON)Monitor range−100 % to +100 % of the rated output voltage
Output voltage range−5 V to +5 V or −10 V to +10 V (Selectable)
Accuracy±(1 % of rating)

*1 Select either current control or power control.

External digital input
ZOOM
ItemCommon to all models
Fixed input points1 point (Polarity switchable)
Selected input points5 points (Polarity switchable)
Input formPhotocoupler isolated input (Applicable to both current sink / source output)
Fixed functionALARM INHIGH alarm occurrence
Selecting functionOFFDo not use terminals
OUTPUT ONTurn on the output
OUTPUT OFFTurn off the output
OUTPUT CTRLTurn on of off the output
L ALARM INLOW alarm occurrence
ALARM CLRLOW alarm clearance
SEQ RUNSequence start/end
SEQ PAUSESequence pause/resume
INTEG CTRLStarting/stopping integration measurement
INTEG RESETResetting integration measurement data
ACQUIRE TRIGInput the measurement trigger
SEQ TRIG INInput the trigger for sequence
MEM1 RECALLRecall preset memory 1
MEM2 RECALLRecall preset memory 2
External circuit power supply range12 V to 24 Vdc (±10 %)
External digital output
ZOOM
ItemCommon to all models
Output points6 points (Polarity switchable)
Output formSemiconductor relay output
Selecting functionOFFDo not use terminals
OUTPUT ONOutputting the signal while the output is ON
POWER ONSignal is output when power supply is on and output is possible
H ALARM OUTOutput a signal when a HIGH alarm occurs
L ALARM OUTOutput a signal when a LOW alarm occurs
CC STATUSOutput a signal when operating in the CC mode
CV STATUSOutput a signal when operating in the CV mode
SEQ TRIG OUTOutput the trigger for sequence
SEQ STATUSSignal is output while the sequence is running
EXT DIN BUSYOutput a signal when the digital input is in BUSY status
MEM1 ACT TIMESignal is output when the setting is completed for preset memory 1
MEM2 ACT TIMESignal is output when the setting is completed for preset memory 2
RELAY DRIVEOutput a signal after approx. 100 ms in step with on/off of the DC OUTPUT terminal output. You can set this parameter to only Ch.6.
Communication interface
ZOOM
ItemCommon to all models
Common specificationsSoftware protocolIEEE std. 488.2-1992
Command languageComplies with SCPI Specification 1999.0
RS232CHardwareD-SUB 9-pin connector
Baud rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Data length: 8 bits, Stop bits: 1 bit, Parity bit: None
Flow control: No, CTS-RTS
Program message terminatorLF during reception, LF during transmission.
USB (device)HardwareStandard type B socket.
Complies with the USB 2.0 specifications; data rate: 480 Mbps (high speed)
Program message terminatorLF or EOM during reception, LF + EOM during transmission
Device classComplies with the USBTMC-USB488 device class specifications
USB (host)HardwareStandard type A socket.
Complies with the USB 2.0 specifications; data rate: 480 Mbps (high speed)
LANHardwareIEEE 802.3 100BASE-TX or 10BASE-T Ethernet
Communication protocolSCPI-RAW, SCPI-Telnet, HiSLIP, VXI-11
Program message terminatorSCPI-RAW: LF during reception, LF during transmission
HiSLIP: LF or END during reception, LF + END during transmission.
Compliant standardsLXI Version 1.5 Specifications 2016
Others
ZOOM
ItemCommon to all models
Synchronization function (clock synchronization)OverviewSYNC icon is displayed on the display when synchronization is established with the internal clock after connecting with other PXB series using the EXT SYNC connector.
Sequence synchronizationSynchronization of the program start and step start.
Measurement synchronizationSynchronization of the measurement start
Output synchronizationSynchronization of output ON/OFF
Sequence functionOperation modeCV, CC, and CP modes
Maximum number of programs30
Maximum number of steps10000
Step execution time1 ms to 3600 000 s
Loop count1 to 100000, or infinite
Sine functionOperation modeCV/CC mode
Frequency setting range1 Hz to 1000 Hz
Frequency resolution1 Hz to 10 Hz0.2 Hz
12 Hz to 100 Hz2 Hz
120 Hz to 1000 Hz20 Hz
CVMaximum settingSetting range up to 105 % of rated voltage
Maximum offset settingSetting range up to 105 % of rated voltage
CCMaximum settingSetting range up to 210 % of rated current
Maximum offset settingSetting range up to ±105 % of rated current
Pulse functionOperation modeCV/CC mode
Frequency setting range1 Hz to 1000 Hz
Frequency resolution1 Hz to 10 Hz0.01 Hz
12 Hz to 100 Hz0.1 Hz
120 Hz to 1000 Hz1 Hz
CVHigh level rated currentSetting range up to 105 % of rated voltage
Low level rated currentSetting range up to 105 % of rated voltage
CCHigh level rated currentSetting range up to 105 % of rated current
Low level rated currentSetting range up to 105 % of rated current
Duty cycle2.5 % to 97.5 %
Measurement triggerMeasurement start condition (trigger source)Conditions for starting measurement can be selected (when inputting from display, when inputting commands by remote control, when inputting signals by external control, and when operating in synchronization)
Number of measurements1 to 65536
Measurement delay timeSetting range0 s to 100 s
Resolution0.1 ms
Measurement intervalSetting range0.1 ms to 3600 s
Resolution0.1 ms
Measurement timeSetting range0.1 ms to 1 s
Resolution0.1 ms
I-V characteristic functionOperation modeCV/CC mode
Number of setup items3 to 100 items (interpolated between points with straight lines)
Preset memoryNumber of memory entries20
Saved settingValues in CV, CC, and CP modes, protection function values, and IR values
Setup MemoryNumber of memory entries21
Saved settingOn/off of the output from the DC OUTPUT terminal, Output voltage value/Output current value/Output power value, Output current for seamless operation (DC SEAM), Output mode, Response, Slew Rate, Priority operation mode (Priority when output is ON), Impedance Setting When the Output is Off (Impedance when output is OFF), Value of the pulse function (Duty, Frequency, High, Low), Value of the sine function (Amplitude, Frequency, Offset), Number of I-V characteristics (Count), Internal resistance value (IR), Over voltage protection (OVP), Under voltage protection (UVP, UVP Enable), Over current protection (OCP(+), OCP(-), Delay), Over power protection (OPP(+), OPP(-)), Line overvoltage protection (Line OVP), Measurement trigger settings (Source, Count, Delay, Enable, Timer), Integration settings (Gate, Reset)
key lockLevel 1Output on/off and preset memory recall are available
Level 2Output on/off are available
Level 3Output off is available
Number of units in parallel operationUp to 10 units
General specifications
ZOOM
ItemPXB20K-50PXB20K-250PXB20K-500PXB20K-1000PXB20K-1500
WeightApprox. 41 kg (90.39 lbs)Approx. 39 kg(85.98 lbs)Approx. 38 kg (83.78 lbs)Approx. 37 kg (81.57 lbs)Approx. 37 kg (81.57 lbs)
Dimensions430 (16.93)W×128 (5.04)H×720 (28.35)Dmm (inches) For details, refer to the dimensional drawing.
Environmental conditionsOperating environmentIndoor use, overvoltage category II
Operating temperature0 °C to +40 °C (32 °F to +104 °F)0 °C to +50 °C (32 °F to +122 °F)
Operating humidity20 % rh to 85% rh (no condensation)
Storage temperature−25°C to +60°C (−13 °F to +140 °F)
Storage humidity90 % rh or less (no condensation)
AltitudeUp to 2000m
Cooling systemForced air cooling using fan
AccessoriesInput terminal cover, External control connector kit (1 set), Chassis connection wire, OUTPUT terminal cover, DC OUTPUT terminal screws (1 pair), EXT SYNC connector cover, SENSING connector cover, SENSING connector (2 pc.), Synchronized operation signal cable kit, Safety Information (1 copy), China RoHS sheet (1 sheet), Getting Started Guide (1 copy), Heavy object warning label (1 pc.)
Withstanding voltageBetween input and GND2200 Vac for 1 minute
Between input and output
Between output and GND500 Vdc for 1 minute1000 Vdc for 1 minute1800 Vdc for 1 minute1800 Vdc for 1 minute3000 Vdc for 1 minute
Insulation resistanceBetween input and GND30 MΩ, 500 Vdc
Between input and output30 MΩ, 500 Vdc30 MΩ, 600 Vdc30 MΩ, 1000 Vdc
Isolation voltage±250 V±600 V±1000 V±1000 V+2000 V/−1000 V
Electromagnetic compatibility (EMC) *1 *2Conforms to the requirements of the directive and standard below.
EMC Directive 2014/30/EU
EN 61326-1 (Class A*3)
Safety*1Conforms to the requirements of the directive and standard below.
Low Voltage Directive 2014/35/EU*2
EN 61010-1 (Class I *4, Overvoltage category II, Pollution Degree 2 *5)

*1. Does not apply to specially ordered or modified products. *2. Only for models with CE marking / UKCA marking on their body. *3. This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *4. This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded. *5. Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.

  • 項目PXB20K-50PXB20K-500PXB20K-1000PXB20K-1500
    定格電力±20000 W±20000 W±20000 W±20000 W
    定格電圧 (ソース) *10V ~ 50V0V ~ 500V0V ~ 1000V0V ~ 1500V
    動作電圧 (シンク) *2 3V ~ 50V10V ~ 500V20V ~ 1000V30V ~ 1500V
    定格電流 *1±800 A±120 A±60 A±30 A
    • *1 最大出力電力によって制限されます。
    • *2 定格電流を流すことができる動作電圧

  • 項目PXB20K-50PXB20K-500PXB20K-1000PXB20K-1500
    設定可能最大電圧52.5V525V1050V1575V
    設定確度±(0.2 % of setting + 0.1 % of rating)
    設定分解能0.005V0.05V0.1V0.1V
    電源変動 *1±10mV±100mV±200mV±300mV
    負荷変動 *2±40mV±250mV±500mV±750mV
    リモートセンシング 最大補償電圧(往復)10% of rating10% of rating10% of rating10% of rating
    内部抵抗設定上限値63m Ω5250m Ω21000m Ω63000m Ω
    レスポンス切り替えFAST、SLOWFAST、SLOWFAST、SLOWFAST、SLOW
    スルーレート切り替え(TYP)12.5 V/ms以上 *3125 V/ms以上 *3250 V/ms以上 *3375 V/ms以上 *3
    12.5 V/ms125 V/ms250 V/ms375 V/ms
    1.25 V/ms12.5 V/ms25.0 V/ms37.5 V/ms
    0.125 V/ms1.25 V/ms2.50 V/ms3.75 V/ms
    0.0125 V/ms0.125 V/ms0.250 V/ms0.375 V/ms
    ソース のみ *4過渡応答 *58ms 以下8ms 以下10ms 以下10ms 以下
    リップルノイズ*6p-p *7250mV1000mV1500mV2500mV
    rms *830mV250mV500mV750mV
    立上り時間 *9全負荷 *1010ms10ms10ms10ms
    無負荷10ms10ms10ms10ms
    立下り時間 *11全負荷 *1010ms10ms10ms10ms
    無負荷10ms10ms10ms10ms
    • *1 200Vac入力では180Vac ~ 252Vac、400Vac入力では342Vac ~ 504Vac です。一定負荷において。
    • *2 定格出力電圧で、負荷を無負荷から全負荷(定格出力電力/定格出力電圧)まで変化させたときの変化量です。センシングポイントにて測定。
    • *3 ディスプレイにはMAX と表示されます。
    • *4 CVモードのレスポンス設定がFASTの場合。
    • *5 出力電圧が定格出力電圧の ±(0.1% + 10mV)以内に復帰する時間です。負荷電流の変動値は、設定した出力電圧での最大電流の50% ~ 100%です。
    • *6 定格出力電流時。JEITA RC-9131C のプローブを使用し、100:1 プローブを使用して測定した値です。
    • *7 測定周波数帯域 10Hz ~ 20MHz
    • *8 測定周波数帯域 10Hz ~ 1MHz
    • *9 定格出力電圧の10%から90%の変化に対して適用されます。
    • *10 純抵抗使用時
    • *11 定格出力電圧の90%から10%の変化に対して適用されます。

  • 項目PXB20K-50PXB20K-500PXB20K-1000PXB20K-1500
    設定可能最大ソース電流+840A+126A+63A+31.5A
    設定可能最大シンク電流-840A-126A-63A-31.5A
    シームレス設定電流範囲-840A ~ +840A-126A ~ +126A-63A ~ +63A-31.5A ~ +31.5A
    設定確度±(0.75% of rating)±(0.75% of rating)±(0.75% of rating)±(0.75% of rating)
    設定分解能0.1A0.01A0.005A0.002A
    電源変動± 1600mA± 240mA± 120mA± 60mA
    負荷変動± 1600mA± 240mA± 120mA± 60mA
    立上り時間(短絡)(TYP)*15ms5ms5ms5ms
    立下り時間(短絡)(TYP)*25ms5ms5ms5ms
    充放電切り替え時間(TYP)10ms10ms10ms10ms
    レスポンス切り替えFAST, SLOWFAST, SLOWFAST, SLOWFAST, SLOW
    スルーレート切り替え(TYP)200A/ms 以上*330A/ms 以上*315A/ms 以上*37.5A/ms 以上*3
    200A/ms30A/ms15A/ms7.5A/ms
    20A/ms3A/ms1.5A/ms0.75A/ms
    2A/ms0.3A/ms0.15A/ms0.075A/ms
    0.2A/ms0.03A/ms0.015A/ms0.0075A/ms
    • *1 CC モードのレスポンス設定が FAST の場合。定格出力電流の 10% から 90% の変化に対して適用されます。
    • *2 CC モードのレスポンス設定が FAST の場合。定格出力電流の 90% から 10% の変化に対して適用されます。
    • *3 ディスプレイにはMAX と表示されます。

  • 項目全機種共通
    設定可能最大ソース電力+21000W
    設定可能最大シンク電力-21000W
    シームレス設定電力範囲-21000W ~ +21000W
    設定確度 *1±(0.5% of power rating + 0.5% of current rating × Vout)
    設定分解能2W
    • *1 定格電力の 5% 以上から保証されます。定格電力の 5% 未満は TYP 値として保証されます。

  • 項目全機種共通
    公称入力定格200Vac ~ 240Vac, 50Hz ~ 60Hz
    入力電圧範囲180Vac ~ 252Vac
    入力周波数範囲47Hz ~ 63Hz
    入力電流(最大値)*180A(180V)
    入力電力(最大値)*124kVA
    突入電流(TYP)*2130A
    力率(TYP)*10.96
    出力保持時間10ms 以上
    • *1 定格出力電流における定格出力電力のとき。
    • *2 POWER スイッチをオンにしたときのピーク電流最大値です。(入力フィルタのコンデンサへのサージ電流は除く)

  • 項目全機種共通
    公称入力定格380Vac ~ 480Vac, 50Hz ~ 60Hz
    入力電圧範囲342Vac ~ 504Vac
    入力周波数範囲47Hz ~ 63Hz
    入力電流(最大値)*140A(342V)
    入力電力(最大値)*124kVA
    突入電流(TYP)*270A
    力率(TYP)*10.96
    出力保持時間10ms 以上
    • *1 定格出力電流における定格出力電力のとき。
    • *2 POWER スイッチをオンにしたときのピーク電流最大値です。(入力フィルタのコンデンサへのサージ電流は除く)

  • 項目PXB20K-50PXB20K-500PXB20K-1000PXB20K-1500
    電圧計最大表示± 60.000V± 600.00V± 1200.00V± 1800.00V
    表示確度±(0.1% of reading + 0.2% of rating)
    電流計最大表示電流± 960.000A± 168.000A± 72.000A± 42.000A
    表示確度±(0.75 % of rating)
    電力計最大表示電力*1± 24.000kW
    表示確度電圧計と電流計の積算値を表示
    動作表示出力オン/オフ前面パネルの OUTPUT LED が緑色に点灯
    動作モードディスプレイ左上部に下記を表示
    CV モード時:CV アイコン
    CC モード時:CC アイコン
    CP モード時:CP アイコン
    リモート(LAN)ディスプレイ左上部に下記を表示
    非接続:赤色の LAN アイコン
    接続準備中:橙色の LAN アイコン
    接続中:緑色の LAN アイコン
    アラーム作動した保護機能の内容をディスプレイに表示
    SCPI エラー現在発生しているエラーをディスプレイに表示
    POWER オフ残留電荷警告、ディスプレイが消灯してから再起動をする旨を表示
    キーロックキーロックの状態をディスプレイ右上部に表示
    センシングセンシング有効時にはディスプレイ右上部にセンシングアイコンを表示
    並列運転時スレーブ機にスレーブ機の状態を表示
    • *1 10kW未満は単位がWになります。

  • An alarm not requiring a reboot to be cleared.

    項目PXB20K-50PXB20K-500PXB20K-1000PXB20K-1500
    OVP (過電圧保護)保護動作出力オフ、ディスプレイに「OVP」表示。スレーブ機では「SLV OVP」表示。
    設定範囲5V 〜 55V50V 〜 550V100V 〜 1100V150V 〜 1650V
    設定確度±(0.1% of setting + 0.2% of rating)
    OCP (過電流保護)保護動作出力オフ、ディスプレイに「OCP」表示。スレーブ機では「SLV OCP」表示。
    設定範囲(ソース)80A 〜 880A12A 〜 132A6A 〜 66A3A 〜 33A
    設定範囲(シンク)-80A 〜 -880A-12A 〜 -132A-6A 〜 -66A-3A 〜 -33A
    設定確度±(0.75 % of rating)
    OPP (過電力保護)保護動作出力オフ、ディスプレイに「OPP」表示。スレーブ機では「SLV OPP」表示。
    設定範囲(ソース)2kW 〜 24kW
    設定範囲(シンク)-2kW 〜 -24kW
    設定確度±(1.0% of power rating +1.0% of current rating × Vout)
    UVP (低電圧保護)保護動作出力オフ、ディスプレイに「UVP」表示。スレーブ機では「SLV UVP」表示。
    設定範囲0V 〜 50V0V 〜 500V0V 〜 1000V0V 〜 1500V
    選択可能Enable / Disable
    設定確度±(0.1% of setting + 0.2% of rating)
    Watchdog Alarm (通信異常保護)保護動作出力オフ、ディスプレイに「WDOG」表示
    設定範囲1s 〜 3600s
    選択可能Enable / Disable
    External Alarm LOW Level (外部入力アラーム検出)保護動作出力オフ、ディスプレイに「EXT LOW」表示
     

  • An alarm requiring a reboot to be cleared.

    項目全機種共通
    Reverse Alarm (逆接続検出保護)保護動作出力オフ、ディスプレイに「REVE」表示。
    OHP (過熱保護)保護動作出力オフ、ディスプレイに「OHP」表示。スレーブ機では「SLV OHP」表示。
    Line OVP (系統過電圧保護)保護動作出力オフ、ディスプレイに「LOVP」表示。スレーブ機では「SLV LOVP」表示。
    設定範囲入力電圧定格 200Vac モデル:200V 〜 258V
    入力電圧定格 400Vac モデル:380V 〜 516V
    Line UVP (糸統低電圧保護)保護動作出力オフ、ディスプレイに「LUVP」表示。スレーブ機では「SLV LUVP」表示。
    設定範囲入力電圧定格 200Vac モデル:175V 以下
    入力電圧定格 400Vac モデル:333V 以下
    Line Frequency Error (系統周波数異常保護)保護動作出力オフ、ディスプレイに「FREQ」表示。スレーブ機では「SLV FREQ」表示。
    検出値42Hz / 68Hz
    External Alarm HIGH Level (外部入力アラーム検出)保護動作出力オフ、ディスプレイに「EXT HIGH」表示
    SENS Alarm (センシング誤接続検出)保護動作出力オフ、ディスプレイに「SENS」表示
    設定値Enable / Disable
    Parallel Communication Error (並列運転通信異常検出)保護動作出力オフ、ディスプレイに「PARA COM」表示
    Para Other Slave Alarm (並列運転 Slave 異常発生)保護動作出力オフ、ディスプレイに「SLV OTHR」表示
    Incorrect Slave Alarm (対象外機器接続)保護動作出力オフ、ディスプレイに「SLV INC」表示
    Too many connections (過剰並列接続)保護動作出力オフ、ディスプレイに「TOO MANY」表示
    Hardware ERR *1 (ハードウェアエラー)保護動作出力オフ、ディスプレイに「ERRH」表示。スレーブ機では「SLV ERRH」表示。
    Software ERR *2 (ソフトウェアエラー)保護動作出力オフ、ディスプレイに「ERRS」表示。スレーブ機では「SLV ERRS」表示。
    • *1 ハードウェアに関連する異常が検出され、内部ユニットが緊急停止した場合に発生します。
    • *2 ソフトウェアに関連する異常が検出され、内部ユニットが緊急停止した場合に発生します。

  • 項目全機種共通
    入力部入力点数2点
    外部出力電圧制御 (CV)設定範囲定格出力電圧の 0% ~ +100%
    入力電圧範囲0V 〜 +5V または 0V 〜 +10V(選択可)
    確度±(1% of rating)
    外部電流制御(CC)
    外部電力制御(CP) *1
    設定範囲定格電流、定格電力の -100% 〜 +100%
    入力電圧範囲-5V 〜 +5V または -10V 〜 +10V(選択可)
    確度±(1% of rating)
    出力部出力点数2点
    電圧モニタ(VMON) モニタ範囲定格出力電圧の 0% 〜 +100%
    出力電圧範囲0V 〜 +5V または 0V 〜 +10V(選択可)
    確度1% of rating
    電流モニタ(IMON) モニタ範囲定格出力電流の -100% 〜 +100%
    出力電圧範囲-5V 〜 +5V または -10V 〜 +10V(選択可)
    確度±(1% of rating)
    • *1 電流制御、電力制御のどちらかを選択

  • 項目全機種共通
    固定入力点数1点(極性切り替え可能)
    選択入力点数5点(極性切り替え可能)
    入力形式フォトカプラ絶縁入力(電流シンク/ソース出力両対応)
    固定機能ALARM INHIGH アラームの発生
    選択機能OFF端子を使用しない
    OUTPUT ON出力をオンにする
    OUTPUT OFF出力をオフにする
    OUTPUT CTRL出力をオン/オフする
    L ALARM INLOW アラームの発生
    ALARM CLRLOW アラームの解除
    SEQ RUNシーケンスの開始/終了
    SEQ PAUSEシーケンスの停止/再開
    INTEG CTRL積算計測の開始/停止
    INTEG RESET積算計測データをリセット
    ACQUIRE TRIG計測用のトリガを入力
    SEQ TRIG INシーケンス用のトリガを入力
    MEM1 RECALLプリセットメモリー1を呼び出す
    MEM2 RECALLプリセットメモリー2を呼び出す
    外部回路電源範囲12V 〜 24Vdc(± 10%)
     

  • 項目全機種共通
    出力点数6 点(極性切り替え可能)
    出力形式半導体リレー出力
    選択機能OFF端子を使用しない
    OUTPUT ON出力オン時に信号を出力
    POWER ON電源がオンで出力できるとき信号を出力
    H ALARM OUTHIGH アラームが発生したとき信号を出力
    L ALARM OUTLOW アラームが発生したとき信号を出力
    CC STATUSCC モードで動作したときに信号を出力
    CV STATUSCV モードで動作したときに信号を出力
    SEQ TRIG OUTシーケンス用のトリガを出力
    SEQ STATUSシーケンス実行時に信号を出力
    EXT DIN BUSYデジタル入力が BUSY 状態のとき信号を出力
    MEM1 ACT TIMEプリセットメモリー 1 に設定が完了したとき信号を出力
    MEM2 ACT TIMEプリセットメモリー 2 に設定が完了したとき信号を出力
    RELAY DRIVEDC OUTPUT 端子の出力オン/オフと連動し、時間差約 100 ms の信号を出力。Ch.6 にのみ設定可能。
     

  • 項目全機種共通
    共通仕様ソフトウェアプロトコルIEEE std. 488.2-1992
    コマンド言語SCPI Specification 1999.0 仕様に準拠
    RS232CハードウェアD-SUB 9 ピンコネクタ
    ボーレート:1200 / 2400 / 9600 / 19200 / 38400 / 57600 / 115200 bps
    データ長:8bit、ストップビット:1bit、パリティビット:なし
    フロー制御:なし/ CTS-RTS
    プログラムメッセージターミネータ受信時 LF、送信時 LF
    USB
    (デバイス)
    ハードウェア標準 B タイプソケット
    USB2.0 仕様に準拠、通信速度 480 Mbps(High Speed)
    プログラムメッセージターミネータ受信時:LF or EOM、送信時:LF + EOM
    デバイスクラスUSBTMC-USB488 デバイスクラス仕様に準拠
    USB
    (ホスト)
    ハードウェア標準 A タイプソケット
    USB2.0 仕様に準拠、通信速度 480 Mbps(High Speed)
    LANハードウェアIEEE 802.3 100BASE-TX/10BASE-T Ethernet
    通信プロトコルSCPI-RAW、SCPI-Telnet、HiSLIP、VXI-11
    プログラムメッセージターミネータSCPI-RAW:受信時 LF 、送信時 LF
    HiSLIP: 受信時 LF または END、送信時 LF + END
    対応規格LXI Version 1.5 Specifications 2016
     

  • 項目全機種共通
    同期機能 (クロック同期)概要EXT SYNC コネクタを使用してほかの PXB シリーズと接続したあと、 内部クロックでの同期を確立するとディスプレイに SYNC アイコンが表示される。
    シーケンス同期プログラムの開始、ステップの開始を同期
    測定同期測定の開始を同期
    出力同期出力オン/オフを同期
    シーケンス機能動作モードCVモード、CCモード、CPモード
    最大ブログラム数30
    最大ステップ数10000
    ステップ実行時間1ms 〜 3600000s
    ループ回数1 ~ 100000、または無限
    サイン機能動作モードCVモード、CCモード
    周波数設定範囲*11Hz 〜 1000Hz
    周波数設定 分解能1Hz 〜 10Hz0.2Hz
    12Hz ~ 100Hz2Hz
    120Hz ~ 1000Hz20Hz
    CV最大設定値定格電圧の105 %まで設定可能
    最大オフセット設定定格電圧の105 %まで設定可能
    CC最大設定値定格電流の210 %まで設定可能
    最大オフセット設定定格電流の± 105% まで設定可能
    バルス機能動作モードCVモード、CCモード
    周波数設定範囲*11Hz 〜 1000Hz
    周波数設定 分解能1Hz 〜 10Hz0.01Hz
    12Hz ~ 100Hz0.1Hz
    120Hz ~ 1000Hz1Hz
    CVHighレベル定格電流定格電圧の105%まで設定可能
    Lowレベル定格電流定格電圧の105%まで設定可能
    CCHighレベル定格電流定格電流の105%まで設定可能
    Lowレベル定格電流定格電流の105%まで設定可能
    デューティ比2.5% 〜 97.5%
    測定トリガ測定開始条件(トリガソース)測定開始の条件を選択可能 (ディスプレイから入力時、 リモートコントロールでコマンド入力時、外部コントロールで信号を入力時、同期操作時)
    測定回数1 ~ 65536
    測定遅延時間設定範囲0s 〜 100s
    設定分解能0.1ms
    測定間隔設定範囲0.1ms 〜 3600s
    設定分解能0.1ms
    測定時間設定範囲0.1ms 〜 1s
    設定分解能0.1ms
    I-V 特性機能動作モードCVモード、CCモード
    設定項目数3点~ 100点(点と点との間は直線で補間)
    プリセットメモリーメモリー数20
    保存項目CV、CC、CP 各モードでの設定値、保護機能設定値、IR 設定値
    セットアップメモリーメモリー数21
    保存項目積算値を記録する条件、積算値をリセットする条件、プリセットメモリーを呼び出すときの確認動作
    DC OUTPUT 端子からの出力オン/オフ、測定 1 回あたりの記録時間、測定値の記録回数
    優先動作モード、出力オフ時のインピーダンス設定、負荷設定値(電圧値/電流値/電力値/抵抗値)
    出力モード、I-V 特性、保護機能(過電流保護/過電圧保護/低電圧保護/過電力保護/系統過電圧保護)
    パルス機能の設定値、サイン機能の設定値、レスポンス、スルーレート
    測定トリガ適用の遅延時間、測定間隔、測定のトリガソース
    キーロックLevel1出力オン/オフとプリセットメモリーの呼び出しが可能
    Level2出力オン/オフが可能
    Level3出力オフが可能
    並列運転台数最大10台
    • *1 PXBシリーズの出力ゲイン特性により、Frequencyを100Hz以上に設定すると出力が減衰します。

  • 項目PXB20K-50PXB20K-500PXB20K-1000PXB20K-1500
    質量約41kg約38kg約37kg約37kg
    寸法430(455)W × 128(160)H × 720(1000)Dmm(最大寸) 詳細は外形寸法図をご参照ください。
    環境条件動作環境屋内使用、過電圧カテゴリII
    動作温度0°C〜 +40°C0°C〜 +50°C
    動作湿度20%rh 〜 85%rh (結露なし)
    保存温度-25°C〜 +60°C
    保存湿度90%rh 以下(結露なし)
    高度2000mまで
    冷却方式ファンによる強制空冷
    付属品INPUT 端子カバー、外部コントロール用コネクタキット(1 組)、シャシ接続線、
    OUTPUT 端子カバー、DC OUTPUT 端子用ねじ(1 組)、EXT SYNC コネクタカバー、SENSING 端子カバー、
    SENSING コネクタ(2 個)、同期運転信号ケーブルキット、安全のために(1 冊)、China RoHS シート(1 枚)、
    CD-ROM(1 枚)、セットアップガイド(1 冊)、クイックリファレンス(和文 1 枚、英文 1 枚)、重量物警告シール(1 枚)
    耐電圧入力 - GND間2200Vac、1 分間
    入力 - 出力間2200Vac、1 分間
    出力 - GND間500Vdc、1 分間1800Vdc、1 分間1800Vdc、1 分間3000Vdc、1 分間
    絶縁抵抗入力 - GND間30M Ω、500Vdc
    入力 - 出力間30M Ω、500Vdc30M Ω、1000Vdc
    対接地電圧± 250V± 1000V± 1000V+2000V / -1000V
    電磁適合性(EMC) *1 *2以下の指令および規格の要求事項に適合
    EMC 指令 2014/30/EU
    EN 61326-1(Class A*3)
    安全性*1以下の指令および規格の要求事項に適合
    低電圧指令 2014/35/EU*2
    EN 61010-1(Class I*4, 過電圧カテゴリII , 汚染度 2*5)
    • *1 特注品、改造品には適用されません。
    • *2 本体に CE マーキング/ UKCA マーキングの表示のあるモデルに対してのみ。
    • *3 本製品は Class A 機器です。工業環境での使用が意図されています。本製品を住宅地区で使用すると干渉の原因となることがあります。
      そのような場合には、ラジオやテレビ放送の受信干渉を防ぐために、ユーザによる電磁放射を減少させる特別な措置が必要となることがあります。
    • *4 本製品は Class I 機器です。本製品の保護導体端子を必ず接地してください。正しく接地されていない場合、安全性は保障されません。
    • *5 汚染とは、絶縁耐力または表面抵抗率の低下を引き起こし得る異物(固体、液体、または気体)が付着した状態です。
      汚染度 2 は、非導電性の汚染だけが存在し、ときどき、結露によって一時的に導電性になり得る状態を想定しています。

Unless specified otherwise, the specifications are for the following settings and conditions.

  • The product is warmed up for at least 30 minutes.

The used terminology is as follows:

  • TYP: These are typical values that are representative of situations where the product operates in an environment with an ambient temperature of 23°C (73.4°F).
  • setting: Indicates a set value.
  • reading: Indicates a readout value.
  • rating: Indicates a rated value.
  • Open: Indicates equivalence to the state in which the DC OUTPUT terminals are opened.
  • +, −: + sign indicates source, − sign indicates sink.
  • Vout: Indicates output voltage.

Line-up

Options

For detailed optional products, please check the individual product page.

Downloads

Rare interview transcripts from those involved in the development of the bi-directional power supply

The electric drive changes the power from the engine to the motor, which converts energy in both directions, so the electrical components (inverter, battery, etc.) that drive the motor are subject to bi-directional current flow.

In the evaluation of these electrical components, the market demanded a power supply that could handle bidirectional current, and the power band varied from 10 kW to several 100 kW, depending on the type of EV, so there was a wide range of power needs. At that time, Kikusui did not have a bi-directional DC power supply or a power supply that could handle several hundred kW, and we decided to develop a bi-directional DC power supply that could sufficiently meet market demands, considering that market needs would increase further if not only cars but all forms of transportation became electrically powered.

xxx

Please feel free to contact us with any questions or concerns.

Download a Product Catalog View List
Request a Quotation Contact Us
close

Search

Entering the model number, capacity, etc.