| Model | PMX18-2A | PMX18-5A | PMX35-1A | PMX35-3A | PMX70-1A | PMX110-0.6A | PMX250-0.25A | PMX350-0.2A | PMX500-0.1A | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Monitor signal output *13 *14 | Voltage monitor (VMON) | At rated voltage output | 10.00 V ± 0.1 V | ||||||||
| At 0 V output | 0.00 V ± 0.1 V | ||||||||||
| Current monitor (IMON) | At rated voltage output | 10.00 V ± 0.1 V | |||||||||
| At 0 A output | 0.00 V ± 0.1 V | ||||||||||
| Status signal output *14 *15 | OUTON STATUS | On when output is on. | |||||||||
| CV STATUS | Turns on during CV operation | ||||||||||
| CC STATUS | Turns on during CC operation | ||||||||||
| ALM STATUS | Turns on when an alarm has been activated | ||||||||||
| PWR ON STATUS | Turns on when the power is turned on | ||||||||||
| External control *16 | EXT-V CV CONT (CV external voltage control) | 0 % to 100 % of the rated output voltage in the range of 0 V to 10 V. | |||||||||
| Accuracy | 1 % of rating +10 mV | 1 % of rating | |||||||||
| EXT-R CV CONT (CV external resistance control) | 0 % to 100 % of the rated output voltage in the range of 0 Ω to 10 kΩ. | ||||||||||
| Accuracy | 1 % of rating +10 mV | 1 % of rating | |||||||||
| EXT-V CC CONT (CC external voltage control) | 0 % to 100 % of the rated output current in the range of 0 V to 10 V. | ||||||||||
| Accuracy | 1 % of rating +5 mA | 1 % of rating | |||||||||
| EXT-R CC CONT (CC external voltage control) | 0 % to 100 % of the rated output current in the range of 0 V to 10 V. | ||||||||||
| Accuracy | 1 % of rating +5 mA | 1 % of rating | |||||||||
| OUTPUT ON/OFF CONT (Output on/off control) | Possible logic selections: Turn the output on using a LOW (0 V to 0.5 V) or short-circuit, turn the output off using a HIGH (4.5 V to 5 V) or open-circuit. Turn the output on using a HIGH (4.5 V to 5 V) or open-circuit, turn the output off using a LOW (0 V to 0.5 V) or short-circuit. | ||||||||||