Item/Model | 400W | 800W | 1200W | 2000W | ||
---|---|---|---|---|---|---|
Monitor signal output | Voltage monitor (VMON) | Selectable monitor voltage range: 0 V to 5 V or 0 V to 10 V | ||||
Accuracy | 2.5 % of f.s. *1 | |||||
Current monitor (IMON) | Selectable monitor voltage range: 0 V to 5 V or 0 V to 10 V | |||||
Accuracy | 2.5 % of f.s. *1 | |||||
Status signal output *2 | OUTON STATUS | On when output is on. | ||||
CV STATUS | Turns on during CV operation | |||||
CC STATUS | Turns on during CC operation | |||||
ALARM STATUS | Turns on when an alarm has been activated | |||||
POWER ON STATUS | Turns on when the power is turned on | |||||
Trigger signal | Input (TRG IN) | Logic selectable: LOW (0 V to 1.5 V), HIGH (3.5 V to 5 V) | ||||
Input impedance: 10 kΩ (TYP) | ||||||
Output (TRG OUT) | Logic selectable: LOW (0 V to 0.6 V), HIGH (4.2 V to 5 V) | |||||
Pulse width: 100 μs (TYP) |
*1. f.s. is the full scale at the selected range. It is 10 V for the 10 V range and 5 V for the 5 V range. *2. Photocoupler open collector output; maximum voltage 30 V, maximum current (sink) 8 mA; isolated from the output and control circuits; status commons are floating (withstand voltage of less than or equal to 60 V); and status signals are not mutually isolated.