PIN NoSignal nameDescription
J1-1VPGMTerminal used to control the output voltage with an external voltage or external resistance. 0 V to 5 V; 0 % to 100 % of the rated output voltage (CF12: LO). 0 V to 10 V; 0 % to 100 % of the rated output voltage (CF12: HI).
J1-2VMONOutput voltage monitor. 0 % to 100 % of the rated output voltage is generated as a voltage between 0 V and 5 V (CF13: LO) or a voltage between 0 V and 10 V (CF13: HI).
J1-3REF OUTReference voltage for external resistance control. 5.25 V (CF12: LO) / 10.5 V (CF12: HI), maximum output current: 2.5 mA.
J1-4PRL ONOn when parallel operation is in use and when output is on (output through an open-collector photo-coupler)
J1-5A GNDExternal signal common for pins 1 to 3, 6 to 9, 11, 12, 14, 16, and 20. When remote sensing is not used, this is at the same electric potential as the negative output terminal. When remote sensing is used, this is at the same electric potential as the negative electrode (-S) of sensing input.
J1-6ALM CLEARAlarm clear terminal. Alarms are cleared when a low level signal(0 V to 0.5 V) is received or shorted.
J1-7I SUMCurrent output terminal for parallel operation.
J1-8PRL OUTPositive output terminal for parallel operation.
J1-9PRL COMP INCorrection signal input terminal for parallel operation.
J1-10A GNDExternal signal common for pins 1 to 3, 6 to 9, 11, 12, 14, 16, and 20. When remote sensing is not used, this is at the same electric potential as the negative output terminal. When remote sensing is used, this is at the same electric potential as the negative electrode (-S) of sensing input.
J1-11IPGMTerminal used to control the output current with an external voltage or external resistance. 0 V to 5 V; 0 % to 100 % of the rated output current (CF12: LO). 0 V to 10 V; 0 % to 100 % of the rated output current (CF12: HI).
J1-12IMONOutput current monitor. 0 % to 100 % of the rated output current is generated as a voltage between 0 V and 5 V (CF13: LO) or a voltage between 0 V and 10 V (CF13: HI).
J1-13PRL COMCommon for pin 4.
J1-14PRL ALMOn when a protection function is activated during parallel operation or when an output shutdown signal is being received.
J1-15A GNDExternal signal common for pins 1 to 3, 6 to 9, 11, 12, 14, 16, and 20. When remote sensing is not used, this is at the same electric potential as the negative output terminal. When remote sensing is used, this is at the same electric potential as the negative electrode (-S) of sensing input.
J1-16SHUT DOWNOutput shutdown control terminal. The output is turned off when set to LOW (0 V to 0.5 V) or shorted.
J1-17OUTPUT CONTOutput on/off terminal. On when set to LOW(0 V to 0.5 V) or shorted; off when set to HIGH(4.5 V or 5 V) or open (CF15: LO) On when set to HIGH(4.5 V to 5 V) or open; off when set to LOW(0 V or 0.5 V) or shorted (CF15: HI)
J1-18PRL COMP OUTCorrection signal output terminal for parallel operation.
J1-19PRL IN-Negative input terminal for parallel operation.
J1-20PRL IN+Positive input terminal for parallel operation.