Output block
Applied Voltage | 0 to 5/ 0 to 10 kV AC and DC
|
---|
AC
Maximum Rated | 500 VA / 10 kV, 50 mA |
---|
Waveforms | Commercial power supply waveform |
---|
Voltage Regulation | Max. 15% (for max. rated load to no load) |
---|
Switching | Use of a zero turn-on switch |
---|
DC
Maximum Rated | 50W / 10 kV, 5 mA |
---|
Ripple | 100 Vp-p typ. at 10 kV, no load 200 Vp-p typ. at max. rated output |
---|
Voltage Regulation | Max. 3% (for max. rated load to no load) |
---|
Output voltmeter
Analog | Scale | 10 kV full scale , AC/DC |
---|
Class | JIS Class 2.5 |
---|
Accuracy | ±5% of full scale |
---|
AC Indication | Mean value response / rms value scale |
---|
Digital | Full Scale | 5 kV/ 10 kV full scale |
---|
Accuracy | ±1.5% of full scale |
---|
AC Response | Mean value response / rms value display |
---|
Ammeter
Digital | Accuracy | ±(5% + 20μA) of upper cutoff current |
---|
AC Response | Mean value response / rms value display |
---|
Pass/fail Judgement Function
Type of Judgement | Window comparator type- ●FAIL judgement
- *When current detected above upper cutoff current
- *When current detected below lower cutoff current (FAIL signal generated when FAIL judgement made)
- ● PASS judgement *When set time has elapsed and no abnormality is detected
|
---|
Upper cutoff current setting range | AC: 0.1 to 55 mA DC: 0.1 to 5.5 mA |
---|
Lower cutoff current setting range | AC: 0.1 to 55 mA DC: 0.1 to 5.5 mA |
---|
Judgment accuracy | ±(5% of upper cutoff current + 20μA) |
---|
Current detection method | Integration of current absolute value followed by comparison with reference value. |
---|
Calibration | Calibration is performed with the rms value of the sine wave, using a pure resistance load. |
---|
No-load output voltage required for detection | Approx. 970 V when set to 50 mA AC |
---|
Approx. 160 V when set to 5 mA DC |
Test Time
Setting range | 0.5 to 999 sec (±10 ms) (timer-off function provided) |
---|
Accuracy | ±20ms |
---|
RS232C interface
Connector | – |
---|
Protocol | – |
---|
Function | – |
---|
AC line power requirements
Line Voltage | 100V±10%, 50/60 Hz (Nominal voltages of 110V, 120V, 220V, 230V and 240V available as factory options.) |
---|
Power Requirements
for line voltage of 100 V | Max. 50 VA under no-load conditions / Approx. 600 VA at rated load |
---|
for line voltage of 100 V to 200 V | Max. 50 VA under no-load conditions / Approx. 600 VA at rated load |
---|
for line voltage of 220 V to 240 V | Max. 50 VA under no-load conditions / Approx. 610 VA at rated load
|
---|
Electromagnetic compatibility (EMC) *1
Conforms to the requirements of the following standard.
EMC Directive 2004/108/EC
EN 61326-1
EN 61000-3-2
EN 61000-3-3
Under following conditions 1. Used HV test leadwires which is supplied.
2. No discharge in testing.
3. Used the shielded cable which length is less than three meters when the SIGNAL I/O is used.
*1 Not applicable to custom order models.
Environment
Specification range | 5 °C to 35°C(41 to 95˚F) / 20 %rh to 80 %rh |
---|
Operable range | 0 °C to 40°C(32 to 104˚F) / 20 %rh to 80 %rh |
---|
Storage range | -20 °C to 70 °C (–4 to 158˚F) / 80 %rh or less |
---|
Dimensions (maximum)
430[16.9 inch] W × 177[6.97 inch] (195[7.68 inch]) H × 370[14.6 inch] (450[17.7 inch]) D mm
Weight
for line voltage of 100 V | Approx. 21 kg (Approx. 46.30 lbs) |
---|
for line voltage of 100 V to 200 V | Approx. 23 kg (Approx. 50.70 lbs) |
---|
for line voltage of 220 V to 240 V | Approx. 24 kg (Approx. 52.91 lbs) |
---|
Accessories
High-voltage test lead | TL01-TOS (max.allowablevoltage: 5 kV /1.5m)
TL03-TOS (max.allowablevoltage: 10 kV /1.5m) |
---|
Dimensions | 14-pin amphenol plug (assembled) |
---|