Item | Description | |
---|---|---|
Constant voltage temperature coefficient | 50 ppm/°C (standard value) | |
Transient response time | Time until the output voltage recovers to within when the output current changes 5 % to 100 %. 50 μs (standard value) | |
Ripple noise | 5Hz to 1MHz, ±3dB bandwidth, average value indication, measured by ground- ing plus or minus output with an rms value display AC voltage waveform | |
Meters | Voltmeter | Maximum display 4 digits |
Accuracy | ±(0.5% of reading+5 digit)*1 | |
Ammeter | Maximum display 4 digits | |
Accuracy | ±(1% of reading+5 digit)*1 | |
Ground | Plus or minus terminal can be grounded | |
Ground voltage | ±250 V DC excluding PAD110-20LA/PAD250-8LA/PAD110-32LA/PAD250- 15LA of which Isolation Voltage is ±500 V | |
Insulation resistance | Chassis-input: 500 V DC 30 MΩ min. Output-chassis: 500 V DC 20 MΩ min. | |
Withstanding voltage | No abnormalities when 1500 VAC applied for 1 minute. | |
Operating temperature range | 0 to +40°C | |
Operating humidity range | 10%rh to 90%rh | |
Cooling system | Forced air cooling using fan | |
Protection devices |
| |
Dimensions | Type Ⅲ | 430(16.93 ̋)W X 218(8.58 ̋)H X 549(21.61 ̋)Dmm(inch) |
Type Ⅳ | 430(16.93 ̋)W X 484.6(19.08 ̋)H X 465(18.31 ̋)Dmm(inch) | |
Accessories | Common specifications | Operation manual : 1 copy , Guard caps : 2 pcs , Weight sticker : 1 sheet |
Type Ⅲ | Power cord : 3-core cabtire cable for 200 VAC 1 pc. ( 3.5 mm2 , approx. 3 m ) | |
Type Ⅳ | Power cord : Single wire cable 3 pcs. ( 8 mm2 , approx. 3 m ) , Cable clamper : 1 set |
*1 At 23°C±5°C.