Model | PMX32-3DU | PMX32-3TR | PMX32-2QU | |
---|---|---|---|---|
Weight (main unit only) | Approx. 13 kg (28.66 lb) | |||
Dimensions (mm(inches)) | 214(8.46)W×124(4.88)(MAX155(6.10))H×400(15.75)(MAX435(17.13))D | |||
Environmental conditions | Operating temperature range | 0 °C to 40 °C (32 °F to 104 °F) | ||
Operating humidity range | 20 %rh to 85 %rh (no condensation) | |||
Storage temperature range | -25°C to 70°C (-13°F to 158°F) | |||
Storage humidity range | 90 %rh or less (no condensation) | |||
Installation location | Indoor use, altitude of up to 2000 m, overvoltage category II | |||
Isolation voltage | Between channel | ±70 Vdc | ||
Between the output and chassis | ±70 Vdc | |||
Withstanding voltage | Between the primary circuit and chassis | No abnormalities at 1500 Vac for 1 minute. | ||
Between the primary and secondary circuits | No abnormalities at 2600 Vac for 1 minute. | |||
Between the secondary circuit and chassis | No abnormalities at 1500 Vdc for 1 minute. | |||
Insulation resistance | Between the primary circuit and chassis | 500 Vdc, 30 MΩ or more | ||
Between the primary and secondary circuits | ||||
Between the secondary circuit and chassis | ||||
Between channel | ||||
Cooling system | Forced air cooling using a fan motor | |||
Common | All channels are independent. The withstanding voltage between channels is ±70 V. | |||
Grounding polarity | Negative grounding or positive grounding possible | |||
Accessories | Power cord: 1 pc. (The attached power cord varies depending on the shipment destination.) Output terminal cover set: 1 set, CD-ROM: 1 disc, Packing list: 1 copy, Safety Information: 1 copy | |||
Electromagnetic compatibility (EMC) *1 *2 | Conforms to the requirements of the directive and standard below. EMC Directive 2014/30/EU EN61326-1 (Class A *3), EN 55011(Class A *3, Group 1 *4) EN 61000-3-2, EN 61000-3-3 Applicable under the following conditions The maximum length of all cabling and wiring connected to the PMX-A must be less than 3 m. | |||
Safety *1 | Conforms to the requirements of the directive and standard below. Low Voltage Directive 2014/35/EU *2 EN 61010-1 (Class I *5 , Pollution Degree 2 *6) |
*1 Does not apply to specially ordered or modified products. *2 Only on models that have the CE marking on the panel. *3 This product confirms to Class A. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *4 This is a Group 1 instrument. This product does not generate and/or use intentionally radiofrequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *5 This product confirms to Class I. Be sure to ground the protective conductor terminal of this product. If not grounded properly, safety is not guaranteed. *6 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only nonconductive pollution will occur except for an occasional temporary conductivity caused by condensation.