25460

PMX-Multi_Parallel operation

ModelPMX32-3DUPMX32-3TRPMX32-2QU
Applicable channelsMaster: CH2, slave: CH1
Constant voltageOperating range0 V to 32 V
Selectable range0 V to 33.6 V
Setting accuracy *10.3 % set + 0.1 % rating
Setting resolution1 mV
Constant currentOperating range0 A to 6 A0 A to 4 A
Selectable range0 A to 6.3 A0 A to 4.2 A
Setting accuracy *10.4 % set + 0.1 % rating
Setting resolution0.2 mA
VoltmeterMaximum display99.999 (fixed decimal point)
Display accuracy *1±(0.5 % of reading + 10 digit)
AmmeterMaximum display9.999 (fixed decimal point)
Display accuracy *1±(1 % of reading + 10 digit)

*1. At an ambient temperature of 23 °C±5 °C.