Model | PMX32-3DU | PMX32-3TR | PMX32-2QU | |
---|---|---|---|---|
Applicable channels | Master: CH2, slave: CH1 | |||
Constant voltage | Operating range | 0 V to 64 V | ||
Selectable range | 0 V to 67.2 V | |||
Setting accuracy *1 *2 | 0.3 % set + 0.1 % rating | |||
Setting resolution | 2 mV | |||
Constant current | Operating range | 0 A to 3 A | 0 A to 2 A | |
Selectable range | 0 A to 3.15 A | 0 A to 2.1 A | ||
Setting accuracy *1 | 0.4 % set + 0.1 % rating | |||
Setting resolution | 0.1 mA | |||
Voltmeter | Maximum display | 99.999 (fixed decimal point) | ||
Display accuracy *1 | ±(0.5 % of reading + 20 digit) | |||
Ammeter | Maximum display | 9.999 (fixed decimal point) | ||
Display accuracy *1 | ±(1 % of reading + 5 digit) |
* 1 At an ambient temperature of 23 °C ±5 °C. * 2 The value is measured at the sensing point.