Item | Common to all models | |
---|---|---|
Fixed input points | 1 point (Polarity switchable) | |
Selected input points | 5 points (Polarity switchable) | |
Input form | Photocoupler isolated input (Applicable to both current sink / source output) | |
Fixed function | ALARM IN | HIGH alarm occurrence |
Selecting function | OFF | Do not use terminals |
OUTPUT ON | Turn on the output | |
OUTPUT OFF | Turn off the output | |
OUTPUT CTRL | Turn on of off the output | |
L ALARM IN | LOW alarm occurrence | |
ALARM CLR | LOW alarm clearance | |
SEQ RUN | Sequence start/end | |
SEQ PAUSE | Sequence pause/resume | |
SEQ TRIG IN | Input the trigger for sequence | |
ACQUIRE TRIG | Input the measurement trigger | |
MEM1 RECALL | Recall preset memory 1 | |
MEM2 RECALL | Recall preset memory 2 | |
INTEG CTRL | Starting/stopping integration measurement | |
INTEG RESET | Resetting integration measurement data | |
External circuit power supply range | 12 V to 24 Vdc (±10 %) |
25460
PXT_External digital input