PXT_各種機能

ItemCommon to all models
Synchronization function (clock synchronization)OverviewSYNC icon is displayed on the display when synchronization is established with the internal clock after connecting with other PXT series using the EXT SYNC connector.
Sequence synchronizationSynchronization of the program start and step start.
Measurement synchronizationSynchronization of the measurement start
Output synchronizationSynchronization of output ON/OFF
Sequence functionOperation modeCV, CC, and CP modes
Maximum number of programs30
Maximum number of steps10000
Step execution time1 ms to 3600000 s
Loop count1 to 100000, or infinite
Output-on/off delay functionSetting range0.0 s to 99.9 s
Resolution0.1 s
Over current protection (OCP) delay functionSetting range1 ms to 2000 ms
Resolution1 ms
Multichannel (VMCB) functionConnection between the master unit and a PCLAN, USB, RS232C
Connection with slave unitsLAN
Measurement triggerMeasurement start condition (trigger source)Conditions for starting measurement can be selected (when inputting from display, when inputting commands by remote control, when inputting signals by external control, and when operating in synchronization)
Number of measurements1 to 65536
Measurement delay timeSetting range0s to 100 s
Resolution0.1ms
Measurement intervalSetting range0.1 ms to 3600 s
Resolution0.1ms
Measurement timeSetting range0.1 ms to 1 s
Resolution0.1ms
I-V Characteristic FunctionOperation modeCV/CC mode
Number of setup items3 to 100 items (interpolated between points with straight lines)
Preset memoryNumber of memory entries20
Saved settingValues in CV, CC, and CP modes, protection function values, IR values, bleeder, and output delay setting.
Setup MemoryNumber of memory entries21
Saved settingOn/off of the output from the DC OUTPUT terminal, Output voltage value/Output current value/Output power value, Output mode, Response, Slew Rate, Priority operation mode (Priority when output is ON), Bleeder, Output delay, Number of I-V characteristics (Count), Internal resistance value (IR), Over voltage protection (OVP), Under voltage protection (UVP, UVP Enable), Over current protection (OCP, Delay), Over power protection (OPP), Line overvoltage protection (Line OVP), Measurement trigger settings (Source, Count, Delay, Enable, Timer), Integration settings (Gate, Reset)
key lockLevel 1Output on/off and preset memory recall are available
Level 2Output on/off are available
Level 3Output off is available
Number of parallel operated load modulesUp to 25 units