Item | Common to all models | ||
---|---|---|---|
Synchronization function (clock synchronization) | Overview | SYNC icon is displayed on the display when synchronization is established with the internal clock after connecting with other PXT series using the EXT SYNC connector. | |
Sequence synchronization | Synchronization of the program start and step start. | ||
Measurement synchronization | Synchronization of the measurement start | ||
Output synchronization | Synchronization of output ON/OFF | ||
Sequence function | Operation mode | CV, CC, and CP modes | |
Maximum number of programs | 30 | ||
Maximum number of steps | 10000 | ||
Step execution time | 1 ms to 3600000 s | ||
Loop count | 1 to 100000, or infinite | ||
Output-on/off delay function | Setting range | 0.0 s to 99.9 s | |
Resolution | 0.1 s | ||
Over current protection (OCP) delay function | Setting range | 1 ms to 2000 ms | |
Resolution | 1 ms | ||
Multichannel (VMCB) function | Connection between the master unit and a PC | LAN, USB, RS232C | |
Connection with slave units | LAN | ||
Measurement trigger | Measurement start condition (trigger source) | Conditions for starting measurement can be selected (when inputting from display, when inputting commands by remote control, when inputting signals by external control, and when operating in synchronization) | |
Number of measurements | 1 to 65536 | ||
Measurement delay time | Setting range | 0s to 100 s | |
Resolution | 0.1ms | ||
Measurement interval | Setting range | 0.1 ms to 3600 s | |
Resolution | 0.1ms | ||
Measurement time | Setting range | 0.1 ms to 1 s | |
Resolution | 0.1ms | ||
I-V Characteristic Function | Operation mode | CV/CC mode | |
Number of setup items | 3 to 100 items (interpolated between points with straight lines) | ||
Preset memory | Number of memory entries | 20 | |
Saved setting | Values in CV, CC, and CP modes, protection function values, IR values, bleeder, and output delay setting. | ||
Setup Memory | Number of memory entries | 21 | |
Saved setting | On/off of the output from the DC OUTPUT terminal, Output voltage value/Output current value/Output power value, Output mode, Response, Slew Rate, Priority operation mode (Priority when output is ON), Bleeder, Output delay, Number of I-V characteristics (Count), Internal resistance value (IR), Over voltage protection (OVP), Under voltage protection (UVP, UVP Enable), Over current protection (OCP, Delay), Over power protection (OPP), Line overvoltage protection (Line OVP), Measurement trigger settings (Source, Count, Delay, Enable, Timer), Integration settings (Gate, Reset) | ||
key lock | Level 1 | Output on/off and preset memory recall are available | |
Level 2 | Output on/off are available | ||
Level 3 | Output off is available | ||
Number of parallel operated load modules | Up to 25 units |
25460
PXT_各種機能
Related specifications : PXT series
- PXT_Lineup
- PXT_Lineup
- PXT_External Control Function-Method
- PXT_External Control Function-connector pin number
- PXT_Bleeder ON/OFF Function
- PXT_General specifications
- PXT_各種機能
- PXT_Communication specifications
- PXT_External digital output
- PXT_External digital input
- PXT_External analog I/O
- PXT_Protection Specifications HIGH alarm
- PXT_Protection function LOW alarm
- PXT_Display
- PXT_400 V three-phase three-wire input
- PXT_200 V three-phase three-wire input
- PXT_Output power
- PXT_Output current
- PXT_Output voltage
- PXT_Output rating