Item | PXT20K-500 | PXT20K-1000 | PXT20K-1500 | |
---|---|---|---|---|
Maximum settable voltage | 525 V | 1050V | 1575 V | |
Setting accuracy | ±(0.2 % of setting + 0.1 % of rating) | |||
Resolution | 0.05 V | 0.1 V | 0.1 V | |
Power fluctuation*1 | ±100mV | ±200mV | ±300mV | |
Load variation*2 | ±250mV | ±750mV | ±750mV | |
Remote sensing Maximum compensation voltage (reciprocating) (TYP) | 10 % of rating | |||
Internal resistance setting upper limit | 5250mΩ | 21000mΩ | 63000mΩ | |
Internal resistance setting resolution | 1mΩ | 2mΩ | 5mΩ | |
Response switching | FAST, SLOW | |||
Slew rate switching | 25V/ms | 50V/ms | 75V/ms | |
12.5 V/ms | 25.0V/ms | 37.5 V/ms | ||
1.25 V/ms | 2.50V/ms | 3.75 V/ms | ||
0.125 V/ms | 0.250V/ms | 0.375 V/ms | ||
Slew rate setting accuracy | ±(20 % of setting +2.5 ms) | |||
Transient response*3 | 6 ms or less | |||
Ripple noise*4 | p-p*5 | 700mV | 1500mV | 1750mV |
rms*6 | 100mV | 250mV | 300mV | |
Rise time*7 | At full load*8 | 25ms | ||
No load | 25ms | |||
Fall time*9 | At full load*8 | 25ms | ||
No load | 750ms |
*1 180 Vac to 252 Vac for 200 Vac input, 342 Vac to 504 Vac for 400 Vac input. At the constant load. *2 The amount of change that occurs when the load is changed from no load to full load (rated output power/rated output voltage) with rated output voltage. The value is measured at the sensing point. *3 The amount of time required for the output voltage to return to a value within the rated output voltage ± (0.1 % + 10 mV) when the response setting of the CV mode is FAST. The load current fluctuation is 50 % to 100 % of the maximum current with the set output voltage. *4 In the case where the CV mode response setting is FAST and having the rated output current. Values measured using JEITA RC-9131C probe and 100:1 probe. *5 Measurement frequency band: 10 Hz to 20 MHz *6 Measurement frequency band: 10 Hz to 1 MHz *7 Applicable to the case where the CV mode response setting is FAST and the rated output voltage changes from 10 % to 90 %. *8 For a pure resistance. *9 Applicable to the case where the CV mode response setting is FAST and the rated output voltage changes from 90 % to 10 %.