What is the maximum input current of PCR-LE series?

The input current for each model of PCR-LE series is as follows:
PCR500LE: 11.3 A (at single-phase, 85 V) / 5.5 A (at single-phase, 170 V)
PCR1000LE: 22 A (at single-phase, 85 V) / 10.8 A (at single-phase, 170 V)
PCR2000LE: 44 A (at single-phase, 85 V) / 21.5 A (at single-phase, 170 V)
PCR3000LE: 66 A (at single-phase, 85 V) / 32 A (at single-phase, 170 V)
PCR4000LE: 88 A (at single-phase, 85 V) / 43 A (at single-phase, 170 V)
PCR6000LE: 64 A (at single-phase, 85 V) / 38 A (at three-phase three-wire, 170 V) / 21 A (at three-phase four-wire, 187 V)
PCR9000LE: 55 A (at three-phase three-wire, 170 V) / 30 A (at three-phase four-wire, 187 V)
For the details, read the user’s manual – chapter of Specifications.