0

KPM1000_General specifications

ItemSpecifications
AC inputNominal input rating100 V to 240 V, 50 Hz to 60 Hz
AC input90 V to 250 V
Maximum power consumption70 VA
Withstanding voltageBetween the voltage and current input terminals and the chassis and interface1980 Vac for 5 minutes
Between the voltage and current input terminals and the AC input
Between the voltage input terminals and the current input terminals
Between the AC input and the chassis1500 Vac for 1 minute
Insulation resistanceBetween the voltage and current input terminals and the chassis and interface100 MΩ or greater at 500 Vdc
Between the voltage and current input terminals and the AC input
Between the voltage input terminals and the current input terminals
Between the AC input and the chassis
Environmental conditionsOperating environmentIndoor use, overvoltage category II
Operating temperature0 °C to +40 °C
Operating humidity20 %rh to 80 %rh (no condensation)
Storage temperature-20 °C to +70 °C
Storage humidity90 %rh or less (no condensation)
Altitude2000 m or less
Earth continuity0.1 Ω or less at 25 Aac
Safety *1Complies with the requirements of the following directive and standard. Complies with the requirements of the following directive and standard Low Voltage Directive 2006/95/EC *2 EN61010-1, class I, pollution degree 2
Electromagnetic compatibility (EMC) *1*2*3Complies with the requirements of the following directive and standard. EMC Directive 2004/108/EC EN61326-1 Compliance condition: The maximum length of all cabling and wiring connected to the KPM1000 must be less than 3 m.
DimensionsSee the outline drawing
WeightApprox. 2.5 kg (5.51 lb.)
AccessoriesPower cord (three-pronged) 1, Safety plugs (solder-connection type) 1 set (red and black), CD-ROM *4 1, Quick start English: 1, Japanese: 1, Safety information 1 (contains English, Chinese, and Japanese) , Packing list 1 (contains both English and Japanese)

*1 Does not apply to specially ordered or modified KPM1000s. *2 Limited to products that have the CE mark on their panels. *3 The measured values may be affected by noise. Use shielded cables for the communication cables. The act of connecting measuring cables may cause radio interference, in which case users may be required to correct the interference.