Item/Model | PBZ20-60 SR | PBZ20-80 SR | PBZ20-100 SR | PBZ40-30 SR | PBZ40-40 SR | PBZ40-50 SR |
---|
Voltage measurement (DC) | Measurement range | 120 % of rating |
---|
Resolution | 0.001 V |
---|
Accuracy *1 | ± (0.05 % of rdng + 0.05 % of rtg) |
---|
Voltage measurement (AC and DC + AC) | Measurement range | AC | 120 % of rating/CF |
---|
DC+AC | 120 % of rating |
---|
Resolution | 0.001 V |
---|
Accuracy*1*2 | 5 Hz<f≦10 kHz | ±(0.5 % of reading + 0.1 % of rating) |
---|
10 kHz<f≦50 kHz | ±(1 % of reading + 0.2 % of rating) |
---|
50 kHz<f≦100 kHz | ±(2 % of reading + 0.2 % of rating) |
---|
Voltage measurement (PEAK) | Measurement range | 120 % of rating |
---|
Resolution | 0.01 V |
---|
Accuracy *1*3 | ±0.5 % of rating |
---|
Current measurement (DC) | Measurement range | 120 % of rating |
---|
Resolution | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A |
---|
Accuracy *1 | ±(0.3 % of reading+0.7 % of rating) | ±(0.3 % of reading+1.0 % of rating) | ±(0.3 % of reading+1.3 % of rating) | ±(0.3 % of reading+0.7 % of rating) | ±(0.3 % of reading+1.0 % of rating) | ±(0.3 % of reading+1.3 % of rating) |
---|
Temperature coefficient | ± (150 ppm / °C of rating) (TYP) |
---|
Current measurement (AC, DC + AC) | Measurement range | AC | 120 % of rating/CF |
---|
DC+AC | 120 % of rating |
---|
Resolution | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A |
---|
Accuracy*1*2 | 5 Hz<f≦10 kHz | ±(3 % of reading + 0.1 % of rating) |
---|
10 kHz<f≦50 kHz | ±(10 % of reading + 1 % of rating) |
---|
Current measurement (PEAK) | Measurement range | 120 % of rating |
---|
Resolution | 0.03 A | 0.04 A | 0.05 A | 0.03 A | 0.04 A | 0.05 A |
---|
Accuracy *1*3 | ±0.5 % of rating |
---|
Measurement time (Aperture) | 100 μs to 3600 s |
---|
Item/Model | PBZ60-20.1 SR | PBZ60-26.8 SR | PBZ60-33.5 SR | PBZ80-15 SR | PBZ80-20 SR | PBZ80-25 SR |
---|
Voltage measurement (DC) | Measurement range | 120 % of rating |
---|
Resolution | 0.001 V |
---|
Accuracy *1 | ± (0.05 % of rdng + 0.05 % of rtg) |
---|
Voltage measurement (AC and DC + AC) | Measurement range | AC | 120 % of rating/CF |
---|
DC+AC | 120 % of rating |
---|
Resolution | 0.001 V |
---|
Accuracy*1*2 | 5 Hz<f≦10 kHz | ±(0.5 % of reading + 0.1 % of rating) |
---|
10 kHz<f≦50 kHz | ±(1 % of reading + 0.2 % of rating) |
---|
50 kHz<f≦100 kHz | ±(2 % of reading + 0.2 % of rating) |
---|
Voltage measurement (PEAK) | Measurement range | 120 % of rating |
---|
Resolution | 0.01 V |
---|
Accuracy *1*3 | ±0.5 % of rating |
---|
Current measurement (DC) | Measurement range | 120 % of rating |
---|
Resolution | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A |
---|
Accuracy *1 | ±(0.3 % of reading+ 0.7 % of rating) | ±(0.3 % of reading+ 1.0 % of rating) | ±(0.3 % of reading+ 1.3 % of rating) | ±(0.3 % of reading+ 0.7 % of rating) | ±(0.3 % of reading+ 1.0 % of rating) | ±(0.3 % of reading+ 1.3 % of rating) |
---|
Temperature coefficient | ± (150 ppm / °C of rating) (TYP) |
---|
Current measurement (AC, DC + AC) | Measurement range | AC | 120 % of rating/CF |
---|
DC+AC | 120 % of rating |
---|
Resolution | 0.003 A | 0.004 A | 0.005 A | 0.003 A | 0.004 A | 0.005 A |
---|
Accuracy*1*2 | 5 Hz<f≦10 kHz | ±(3 % of reading + 0.1 % of rating) |
---|
10 kHz<f≦50 kHz | ±(10 % of reading + 1 % of rating) |
---|
Current measurement (PEAK) | Measurement range | 120 % of rating |
---|
Resolution | 0.03 A | 0.04 A | 0.05 A | 0.03 A | 0.04 A | 0.05 A |
---|
Accuracy *1*3 | ±0.5 % of rating |
---|
Measurement time (Aperture) | 100 μs to 3600 s |
---|