0

PCR-MA_測定値表示

Item/ModelPCR500MAPCR1000MAPCR2000MAPCR4000MA
Voltage measurementResolution0.1 V
Accuracy (output 155 V/310 V range)RMS, AVE *1645 Hz to 65 Hz, DC : ±(0.5 % of reading +0.3 V/0.6 V)
Other than above : ±(0.7 % of reading +0.9 V/1.8 V)
Current measurementResolution0.01 A0 A to 99.99 A (RMS, AVE): 0.01 A 100 A to (RMS, AVE), IPK: 0.1A
Accuracy (output 155 V/310 V range)RMS, AVE *1745 Hz to 65 Hz, DC: ±(0.5 % of reading +0.02 A/0.01 A)
Other than above: ±(0.7 % of reading +0.04 A/0.02 A)
45 Hz to 65 Hz, DC: ±(0.5 % of reading +0.04 A/0.02 A)
Other than above: ±(0.7 % of reading +0.08 A/0.04 A)
45 Hz to 65 Hz, DC: ±(0.5 % of reading +0.08 A/0.04 A)
Other than above: ±(0.7 % of reading +0.16 A/0.08 A)
45 Hz to 65 Hz, DC: ±(0.5 % of reading +0.16 A/0.08 A)
Other than above: ±(0.7 % of reading +0.32 A/0.16 A)
WattmeterResolution0.1W0.1W (<1 000 W), 1 W (1000 W≤)
Accuracy *18±(2 % of reading +0.5 W)±(2 % of reading +1 W)±(2 % of reading +2 W)±(2 % of reading +4 W)

*15 RMS, average (AVE), and power (W) are derived using the following equations.
RMS (true rms computation) = ( Σ (square of the instantaneous voltage or instantaneous current)/ the number of samples.)
AVE = (instantaneous voltage or instantaneous current)/the number of samples
WAC = Σ (instantaneous voltage x instantaneous current)/the number of samples
WDC = VAVG x IAVG
•Sample period: 100 ms to 125 ms for AC output (an integer multiple of the output waveform period. 125 ms for DC output.
•Update interval: Approx. 3 times/s, averaging over 2s when averaging is turned on.
•Peak current value holds the maximum value of the absolute value of the peak current for 0.3s or approximately 5s.
•The voltage display is set to RMS in AC mode and AVE in DC mode.
*16 AC mode: For an output voltage of 13.5 V to 155 V/27 V to 310 V and 23°C ± 5°C. DC mode: For an output voltage of 19 V to 219 V/38 V to 438 V and 23°C ± 5°C. *17 For waveforms with a crest factor of 3 or less. At 5 % to 100 % of the maximum rated current, 23°C ±5°C *18 For an output voltage of 50 V or greater, an output current in the range of 10 % to 100 % of the maximum rated current, a load power factor of 1, an output frequency of 45 Hz to 65 Hz or DC, and 23°C ± 5°C.


Related specifications : PCR-MA Series

Please feel free to contact us with any questions or concerns.

Download a Product CatalogView List
Request a QuotationContact Us