0

PCR-MA_Output voltage stability

Item/ModelPCR500MAPCR1000MAPCR2000MAPCR4000MA
Line regulation *7≤ ±0.15 %
Load variation (output 155 V/310 V range) *840 Hz to 100 Hz, DC : ≤ ±0.15V/±0.3V
Other than above : ≤ ±0.5 V/±1 V
Output frequency variation *9≤ ±1 %
Ripple noise *100.8 Vrms/1.6 Vrms (TYP)
Ambient temperature variation *11100 ppm/°C (TYP)
Output voltage waveform distortion ratio *12≤ 0.5 %
Output voltage response speed *13150 μs (TYP)
Efficiency *14≥ 70 %

*7. For changes in the rated range. *8. For an output voltage of 80 V to 155 V/160 V to 310 V, a load power factor of 1, output voltage variation between 0 A and maximum current, using the output terminal on the rear panel. *9. For an output voltage of 100 V/200 V and a load power factor of 1. Output voltage variation with 60 Hz as a reference. *10. For 5 Hz to 1 MHz components in DC mode using the output terminal on the rear panel. *11. For an output voltage of 100 V/200 V, an output current 0 A, within the operating temperature range. *12. For an output voltage of 50 V to 155 V/100 V to 310 V, a load power factor of 1, in AC mode. *13. For an output voltage of 100 V/200 V, a load power factor of 1, and an output current variation between 0 A and maximum current. *14. For AC mode, at an output voltage of 100 V/200 V, maximum current, a load power factor of 1, and an output frequency of 40 Hz to 500 Hz.