Item/Model | PCR500MA | PCR1000MA | PCR2000MA | PCR4000MA |
---|---|---|---|---|
Line regulation *7 | ≤ ±0.15 % | |||
Load variation (output 155 V/310 V range) *8 | 40 Hz to 100 Hz, DC : ≤ ±0.15V/±0.3V
Other than above : ≤ ±0.5 V/±1 V | |||
Output frequency variation *9 | ≤ ±1 % | |||
Ripple noise *10 | 0.8 Vrms/1.6 Vrms (TYP) | |||
Ambient temperature variation *11 | 100 ppm/°C (TYP) | |||
Output voltage waveform distortion ratio *12 | ≤ 0.5 % | |||
Output voltage response speed *13 | 150 μs (TYP) | |||
Efficiency *14 | ≥ 70 % |
*7. For changes in the rated range. *8. For an output voltage of 80 V to 155 V/160 V to 310 V, a load power factor of 1, output voltage variation between 0 A and maximum current, using the output terminal on the rear panel. *9. For an output voltage of 100 V/200 V and a load power factor of 1. Output voltage variation with 60 Hz as a reference. *10. For 5 Hz to 1 MHz components in DC mode using the output terminal on the rear panel. *11. For an output voltage of 100 V/200 V, an output current 0 A, within the operating temperature range. *12. For an output voltage of 50 V to 155 V/100 V to 310 V, a load power factor of 1, in AC mode. *13. For an output voltage of 100 V/200 V, a load power factor of 1, and an output current variation between 0 A and maximum current. *14. For AC mode, at an output voltage of 100 V/200 V, maximum current, a load power factor of 1, and an output frequency of 40 Hz to 500 Hz.