PLZ-5WH2_Data Logging Function

ConditionSetting rangeDescription
TriggerSet the measurement recording timing and the number of times to record measurements.
SourceEvent (trigger source) that defines the measurement recording condition. Recording starts after the Initiate key is pressed and a trigger is received.
ImmediatePressing Initiate applies a trigger immediately.
BUSApplies a trigger when a *TRG command is received from a PC or when the *TRG key on the front panel is pressed.
DIGITAL2* Applies a trigger when a signal is received at pin 13 of the EXT CONT connector.
MSyncThe triger-application timinig is synced between PLZ-5WH2 units that are synchronized.
TALinkApplies a trigger when a step is executed if Generate is set to TALink in the sequence step settings
Load OffApplies a trigger when the load is turned off.
Count1 to 65536The number of times to recorded measurements.
Delay0 μs to 100 s
(resolution: 10 μs)
The delay time from trigger application until measurement recording.
IntervalDisable/
Enable
Sets whether to insert an interval between recordings when Count is 2 or higher.
Interval Time10 μs to 3600 s
(resolution: 10 μs)
Recording interval time when Interval is set to Enable.
Sense Aperture10 μs to 1 s
(resolution: 10 μs)
Recording time per session. The average value over time is recorded.

*Only when Direction of Digital 2 is set to Input