27806

PLZ-5WH2_EXT CONT connector

Item *1PLZ1005WH2PLZ2005WH2PLZ4005WH2PLZ12005WH2PLZ20005WH2
Load on/off control inputLogic level switchable. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V.
Alarm inputAn alarm is activated with a voltage between 0 V and 1.5 V. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V.
Alarm clearing inputAfter an alarm occurs, eliminate the root cause of the alarm, and change the input to pin 5 of the EXT CONT connector from a low level signal to a high level signal. The alarm will be cleared on the rising edge of this signal. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5.0 V, LOW: 0 V to 1.5 V.
Trigger inputPaused sequence operation resumes when a voltage between 0 V and 0.66 V is received. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 2.31 V to 3.3 V, LOW: 0 V to 0.66 V.
External voltage control input(CC, CR, CP mode)Controls the load settings of CC, CR, CP mode through external voltage input. Input impedance: Approx. 10 kΩ. CC: The setting can be controlled in the range of 0 % to 100 % of the rated current through external voltage input of 0 V to 10 V. CR: The setting can be controlled in the range of 0 % to 100 % of the conductance setting through external voltage input of 0 V to 10 V. CP: The setting can be controlled in the range of 0 % to 100 % of the rated power through external voltage input of 0 V to 10 V.
Setting accuracy±(1 % of rating) (TYP value in CC mode)
External voltage control input (CV mode)The load setting of CV mode can be controlled through external voltage input. The rated voltage can be controlled in the range of 0 % to 100 % with 0 V to 10 V. Input impedance: Approx. 10 kΩ.
Setting accuracy±(1 % of rating) (TYP)
External voltage control input (superimposing in CC mode)Controls the load setting of CC mode by adding current through external voltage input. Adds current in the range of -100 % to 100 % of the rated current for -10 V to 10 V.Input impedance: Approx. 10 kΩ.
Setting accuracy±(1 % of rating) (TYP)
Load-on status outputOn when load is on. Open-collector output from a photocoupler. *2 *2
ALARM 1 outputON when overvoltage detection, reverse-connection detection, overheat detection, front-panel DC INPUT overcurrent detection, alarm input detection, or parallel operation anomaly detection is activated. Open-collector output from a photocoupler. *2 *2
ALARM 2 outputTurns on when OCP, OPP, UVP, or WDP is activated. Open-collector output from a photocoupler. *2
DIGITAL 0 outputCan be controlled through sequences. Output impedance: Approx. 330 Ω. The thresholds are HIGH: 2.5 V to 3.3 V, LOW: 0 V to 0.4 V.
DIGITAL 1 output
DIGITAL 2 input/outputInput/output switchable. Output: Sequence trigger output. The output impedance is 330 Ω.The thresholds are HIGH: 2.5 V to 3.3 V, LOW: 0 V to 0.4 V. Input: Trigger input signal for the sequence and the measurement functions. The thresholds are HIGH: 2.31 V to 3.3 V, LOW: 0 V to 0.66 V
Current monitor outputOutputs 0 V to 10 V for 0 % to 100 % of the rated current. Output impedance: 1 kΩ (TYP).
Accuracy±(1 % of rating) (TYP)

* 1. 1000 V reinforced insulation between each terminal and the DC INPUT terminal * 2. The maximum voltage that can be applied to the photocoupler is 30 V. The maximum current is 4 mA.


Related specifications : PLZ-5WH2 Series

Please feel free to contact us with any questions or concerns.

Download a Product CatalogView List
Request a QuotationContact Us