PLZ-5WH2_Sequence function

Setting rangeSetting itemDescription
By stepLoad valueCurrent, conductance, voltage, power.
The values that can be set depend on the current operation mode.
Slew rateSets the speed of change when the current is changed.
Step execution time0.000050 s to 3600000 s (50 μs to 1000 h), resolution: 1 μs
Load on/off controlTo turn the load on, set the load setting transition method to step or ramp.
OthersTrigger signal setting, trigger signal output
For each programNumber of loops of program1 to 100000 repetitions, or infinite repetitions.
Protection functionsSpecifies the value at which a protection function (OCP, OPP, UVP) is activated.