27806

PLZ-5WH2_Sequence function

ItemPLZ1005WH2PLZ2005WH2PLZ4005WH2PLZ12005WH2PLZ20005WH2
Operation modeCC, CR, CV, CP
Maximum number of programs30
Maximum number of steps10000
Step execution time0.000050 s to 3600000 s (50 µs to 1000 h)
Time resolution1 μs

Related specifications : PLZ-5WH2 Series