PLZ164WL | PLZ334WL | ||
---|---|---|---|
Communication function | GPIB, RS232C, and USB interfaces are equipped as standard. | ||
Input voltage range | 100 Vac to 240 Vac (90 Vac to 250 Vac), single phase, continuous | ||
Input frequency range | 47 Hz to 63 Hz | ||
Power | 95VAmax | ||
Inrush current *1 | 65Amax | ||
Operating temperature range | 0 °C to 40 °C (32 °F to 104 °F) | ||
Operating humidity range | 20 %rh to 85%rh (no condensation) | ||
Storage temperature range | -20 °C to 70 °C (-4 °F to 158 °F) | ||
Storage humidity range | 90 %rh or less (no condensation) | ||
Isolation voltage | ±500V | ||
Insulation resistance | Primary – input terminal | 500 Vdc, 30 MΩ or more (ambient humidity of 70 %rh or less) | |
Primary – chassis | 500 Vdc, 30 MΩ or more (ambient humidity of 70 %rh or less) | ||
Input terminal- chassis | 500 Vdc, 30 MΩ or more (ambient humidity of 70 %rh or less) | ||
Withstanding voltage | Primary – input terminal | No abnormalities at 1500 Vac for 1 minute | |
Primary – chassis | No abnormalities at 1500 Vac for 1 minute | ||
Accessories | Power cord(1 pc.(with plug, length: 2.4 m)), Load input terminal cover(1 pc.), Set of screws for the load input terminal cover(2 sets), Set of screws for the load input terminal(2 sets), Chassis connection wire(1 pc.), CD-R(1 pc.), Setup Guide(1 pc.(Japanese, English), Quick Reference(English:1pc., Japanese:1pc.) | ||
Safety *2 | Conforms to the requirements of the following standard. IEC 61010-1:2001 (Class I, Pollution degree 2) | Complies with the requirements of the following directive and standards. Low Voltage Directive 2014/35/EU, EN 61010-1 (Class I, Pollution degree 2) | |
Weight | Approx. 6.5 kg (14.3 lb.) | Approx. 8 kg (17.6 lb.) | |
Dimensions (mm(inch))(maximum dimensions) | 214.5(8.45″)W×124(155)(4.88″)H×400(455)(15.75″)Dmm |
*1 Approximately 35 A for the input voltage of AC100 V. *2 This product is categorized in the “Class I”. The protective conductor terminal of this product must be connected to the ground. The safety can not be guaranteed when it is not connected to the ground properly.