Item | PXB20K-50 | PXB20K-250 | PXB20K-500 | PXB20K-1000 | PXB20K-1500 | |
---|---|---|---|---|---|---|
Voltmeter | Maximum display | ±60.000 V | ±300.00 V | ±600.00 V | ±1200.00 V | ±1800.00 V |
Display accuracy | ±(0.1 % of reading + 0.2 % of rating) | |||||
Ammeter | Maximum display | ±1120.000 A | ±336.000 A | ±168.000 A | ±84.000 A | ±42.000 A |
Display accuracy | ±(0.75 % of rating) | |||||
Wattmeter | Maximum display *1 | ±24.000 kW | ||||
Display accuracy | Display the integrated value of voltmeter and ammeter | |||||
Operation display | Output ON / OFF | The OUTPUT LED on the front panel lights in green | ||||
Operation mode | Indicate the followings on the upper left part of the display | |||||
CV: CV icon | ||||||
CC: CC icon | ||||||
CP: CP icon | ||||||
Remote (LAN) | Indicate the followings on the upper left part of the display | |||||
Not connected: Red LAN icon | ||||||
Preparing for connection: Orange LAN icon | ||||||
Connected: Green LAN icon | ||||||
Alarm | Indicate the details of activated protection function on the display | |||||
SCPI error | Indicate the error occurring at present on the display | |||||
POWER off | Indicate residual charge warning and an instruction to turn off the display, then reboot | |||||
key lock | Indicate the key lock status on the upper right part of the display | |||||
Sensing | When sensing is enabled, indicate the sensing icon on the upper right part of the display | |||||
During parallel operation | Displaying the slave state on the slave unit | |||||
External control | When digital input/output is enabled, indicate the EXT icon on the upper right part of the display |
*1 The unit will be W if it is less than 10 kW.