25460

PXB_External analog I/O

ItemCommon to all models
InputInput points2 points
Voltage (CV) controlSetting range0 % to 100 % of the rated output voltage
Input voltage range0 V to +5 V or 0 V to +10 V (Selectable)
Accuracy±(1 % of rating)
Current (CC) control
Power (CP) control *1
Setting range−100 % to +100 % of the rated current and rated power
Input voltage range−5 V to +5 V or −10 V to +10 V (Selectable)
Accuracy±(1 % of rating)
OutputOutput points2 points
Voltage monitor (VMON)Monitor range0 % to 100 % of the rated output voltage
Output voltage range0 V to +5 V or 0 V to +10 V (Selectable)
Accuracy1 % of rating
Current monitor (IMON)Monitor range−100 % to +100 % of the rated output voltage
Output voltage range−5 V to +5 V or −10 V to +10 V (Selectable)
Accuracy±(1 % of rating)

*1 Select either current control or power control.