Item | PXB20K-50 | PXB20K-250 | PXB20K-500 | PXB20K-1000 | PXB20K-1500 | |
---|---|---|---|---|---|---|
OVP (Over Voltage Protection) | Protective operation | Output off, indicate “OVP” on the display. SLV OVP is displayed on the slave unit. | ||||
Selectable range | 5 V to 55 V | 25 V to 275 V | 50 V to 550 V | 100 V to 1100 V | 150 V to 1650 V | |
Setting accuracy | ±(0.1 % of setting + 0.2 % of rating) | |||||
Resolution | 0.005 V | 0.02 V | 0.05 V | 0.1 V | 0.1 V | |
OCP (Over Current Protection) | Protective operation | Output off, indicate “OCP” on the display. SLV OCP is displayed on the slave unit. | ||||
Setting range (Source) *1 | 80 A to 880 A | 20 A to 220 A | 12 A to 132 A | 6 A to 66 A | 3 A to 33 A | |
Setting range (Sink) *1 | -80 A to -880 A | -20 A to -220 A | -12 A to -132 A | -6 A to -66 A | -3 A to -33 A | |
Setting accuracy | ±(0.75 % of rating) | |||||
Resolution | 0.1 A | 0.02 A | 0.01 A | 0.005 A | 0.002 A | |
OPP (Over Power Protection) | Protective operation | Output off, indicate “OPP” on the display. SLV OPP is displayed on the slave unit. | ||||
Setting range (Source) *1 | 2 kW to 24 kW | |||||
Setting range (Sink) *1 | -2 kW to -24 kW | |||||
Setting accuracy | ±(1.0 % of power rating +1.0 % of current rating × Vout) | |||||
Resolution | 2 W | |||||
UVP (Under Voltage Protection) | Protective operation | Output off, indicate “UVP” on the display. SLV UVP is displayed on the slave unit. | ||||
Selectable range | 0 V to 50 V | 0 V to 250 V | 0 V to 500 V | 0 V to 1000 V | 0 V to 1500 V | |
Selectable | Enable/Disable | |||||
Setting accuracy | ±(0.1 % of setting + 0.2 % of rating) | |||||
Resolution | 0.005 V | 0.02 V | 0.05 V | 0.1 V | 0.1 V | |
Watchdog Alarm (Communication error protection) | Protective operation | Output off, indicate “WDOG” on the display | ||||
Selectable range | 1 s to 3600 s | |||||
Selectable | Enable/Disable | |||||
External Alarm LOW Level (external input alarm detection) | Protective operation | Output off, indicate “EXT LOW” on the display |
*An alarm not requiring a reboot to be cleared. *1. During parallel operation, this will be the value multiplied by the number of units in the configuration.