Item | PXT20K-500 | PXT20K-1000 | PXT20K-1500 | |
---|---|---|---|---|
Weight | Approx. 38 kg (83.78 lbs) | Approx. 38 kg (83.78 lbs) | Approx. 37 kg (81.57 lbs) | |
Dimensions | 430 (16.93)(MAX455 (17.91))W×128 (5.04)(MAX160 (6.30))H×720 (28.35)(MAX980 (38.58))Dmm(mm (inches)) Refer to Outline Drawing | |||
Environmental conditions | Operating environment | Indoor use, overvoltage category II | ||
Operating temperature | 0 °C to +50 °C (32 °F to +122 °F) | |||
Operating humidity | 20 %rh to 85 %rh (no condensation) | |||
Storage temperature | -25 °C to +60 °C (-13 °F to 140 °F) | |||
Storage humidity | 90 %rh or less (no condensation) | |||
Altitude | Up to 2000 m | |||
Cooling system | Forced air cooling using fan | |||
Accessories | AC INPUT terminal cover, External control connector kit (1 set), Chassis connection wire, DC OUTPUT terminal cover, DC OUTPUT terminal screws (1 pair), EXT SYNC connector cover, SENSING connector cover, SENSING connector (2 pieces), Synchronized operation signal cable kit, Safety Information (1 copy), China RoHS sheet (1 copy), Getting Started Guide (1 copy), Heavy object warning label (1 piece) | |||
Withstanding voltage | Between input and GND | 2200 Vac for 1 minute | ||
Between input and output | ||||
Between output and GND | 1800 Vdc for 1 minute | 1800 Vdc for 1 minute | 3000 Vdc for 1 minute | |
Insulation resistance | Between input and GND | 30 MΩ, 500 Vdc | ||
Between input and output | 30 MΩ, 1000 Vdc | |||
Isolation voltage | ± 1000V | ± 1000V | +2000 V/-1000 V | |
Electromagnetic compatibility (EMC)*1*2 | Conforms to the requirements of the following standard. EMC Directive 2014/30/EU EN 61326-1 (Class A*3) | |||
Safety*1 | Conforms to the requirements of the following standard. Low Voltage Directive 2014/35/EU*2 EN 61010-1 (Class I*4, Overvoltage category II, Pollution Degree 2*5) |
*1 Does not apply to specially ordered or modified products. *2 Only for models with CE marking / UKCA marking on their body. *3 This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *4 This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded. *5 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.