25460

PXT_Protection Specifications HIGH alarm

ItemCommon to all models
Reverse Alarm (Reverse-connection detection protection)Protective operationOutput off, indicate “REVE” on the display
OHP (Overheat protection)Protective operationOutput off, indicate “OHP” on the display. SLV OHP is displayed on the slave unit.
Line OVP (Grid overvoltage protection)Protective operationOutput off, indicate “LOVP” on the display. SLV LOVP is displayed on the slave unit.
Setting rangeInput voltage rating 200 Vac model: 200 V to 258 V
Input voltage rating 400 Vac model: 380 V to 516 V
Line UVP (Grid undervoltage protection)Protective operationOutput off, indicate “LUVP” on the display. SLV LUVP is displayed on the slave unit.
Setting rangeInput voltage rating 200 Vac model: 175 V or less.
Input voltage rating 400 Vac model: 333 V or less.
Line Frequency Error (Grid abnormal frequency protection)Protective operationOutput off, indicate “FREQ” on the display. SLV FREQ is displayed on the slave unit.
Detection value42Hz / 68Hz
External Alarm HIGH Level (External input alarm detection)Protective operationOutput off, indicate “EXT HIGH” on the display
Parallel Communication Error (Parallel operation communication error detected)Protective operationOutput off, indicate “PARA COM” on the display
Para Other Slave Alarm (Parallel operation slave error occurred)Protective operationOutput off, indicate “SLV OTHR” on the display
Incorrect Slave Alarm (Not applicable device connected)Protective operationOutput off, indicate “SLV INC” on the display
Too many connections (Too many parallel connections)Protective operationOutput off, indicate “TOO MANY” on the display
Hardware ERR*1 (Hardware error)Protective operationOutput off, indicate “ERRH” on the display. SLV ERRH is displayed on the slave unit.
Software ERR*2 (Software error)Protective operationOutput off, indicate “ERRS” on the display. SLV ERRS is displayed on the slave unit.

*1 It occurs when an abnormality related to the software is detected and the internal unit comes to an emergency stop. *2 It occurs when an abnormality related to the software is detected and the internal unit comes to an emergency stop.


Related specifications : PXT series

Please feel free to contact us with any questions or concerns.

Download a Product CatalogView List